Inter-laboratory comparison result analysis of noise measurement in simulated workplace in three years
10.11763/j.issn.2095-2619.2020.03.013
- Author:
Guoyong XU
1
,
2
;
Qingsong CHEN
1
,
2
;
Mingzhen LAI
1
,
2
;
Danying ZHANG
1
,
2
;
Hua YAN
1
,
2
;
Bin XIAO
1
,
2
;
Hansheng LIN
1
,
2
Author Information
1. Guangdong Province Hospital for Occupational Disease Prevention and Treatment
2. Guangdong Provincial Key Laboratory of Occupational Disease Prevention and Treatment Guangzhou, Guangdong 510300, China
- Publication Type:Journal Article
- Keywords:
Noise;
Measurement;
Inter-laboratory comparison;
z-score;
Equivalent sound level;
Occupational hygiene technical service organization
- From:
China Occupational Medicine
2020;47(03):310-314
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE: To analyze the influence of noise measuring skills by continuous inter-laboratory comparison among occupational hygiene technical service organizations. METHODS: The results of 68, 55 and 50 occupational hygiene technical service organizations(reference organizations) participating in the inter-laboratory comparison of workplace noise measurement in 2014, 2017 and 2018 respectively were collected. The measurement operation and the calculation of equivalent sound level were evaluated according to the GBZ/T 189.8-2007 Measurement of Physical Agents in Workplace--Part 8: Noise.The measured results were analyzed by z score evaluation method. RESULTS: The results of noise measurement field operation of the reference organizations in the year 2014, 2017 and 2018 show that the accuracy rates of instrument setting was 89.7%, 98.2% and 100.0%, the accuracy rates of measuring position were 52.9%, 81.8% and 94.0%, the accuracy rates of sound level meter holding were 54.4%, 80.0% and 92.0%, the accuracy rates of microphone pointing were 98.5%, 98.2% and 94.0%, and the accuracy rates of noise type recognition were 83.8%, 92.7% and 84.0%, respectively. Among them, the accuracy of instrument setting, measurement position and sound level meter holding showed an increasing trend year by year(P<0.01). The pass rates of measurement results were 91.2%, 94.5% and 88.0% in 2014, 2017 and 2018 respectively. The pass rates of equivalent sound level calculation were 73.5%, 92.7% and 88.0%. The pass rates of comprehensive evaluation were 70.6%, 89.1% and 80.0% respectively. Among them, the pass rates of equivalent sound level calculation and comprehensive evaluation in 2017 were higher than that in 2014(P<0.017). There was no significant difference in the three-year comprehensive assessment total pass rate between private organizations and non-private organizations(84.0 % vs 75.5%, P>0.05). There was no significant difference in the total pass rate of three-year comprehensive evaluation between non-Pearl-River-Delta organizations and Pearl-River-Delta organizations(70.3% vs 81.6%, P>0.05). CONCLUSION: Continuous inter-laboratory comparison in occupational hygiene technical service organizations is beneficial to improve on-site noise measure capability.