Value of transthoracic echocardiography to monitor and evaluate aortic insufficiency after implantation of left ventricular assist device
- VernacularTitle:左室辅助装置植入前后主动脉瓣反流的超声评价和临床预后
- Author:
Yisheng SHI
1
,
2
,
3
,
4
,
5
;
Zhenhui ZHU
1
,
2
,
3
,
4
,
5
;
Hao WANG
1
,
2
,
3
,
4
,
5
;
Juan DU
3
,
4
,
5
,
6
;
Haibo CHEN
3
,
4
,
5
,
7
;
Shengshou HU
3
,
4
,
5
,
7
Author Information
1. Ultrasound Imaging Center, National Center for Cardiovascular Diseases and Fuwai Hospital, Chinese Academy of 
2. Medical 
3. Sciences and 
4. Peking Union Medical 
5. College, Beijing, 100037, P.R.China
6. Postoperative Recovery Center, National Center for Cardiovascular Diseases and Fuwai Hospital, Chinese Academy of Medical 
7. Adult Cardiac Surgery Center, National Center for Cardiovascular Diseases and Fuwai Hospital, Chinese Academy of Medical 
- Publication Type:Journal Article
- Keywords:
Transthoracic echocardiography;
left ventricular assist device;
aortic insufficiency
- From:
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery
2021;28(06):670-674
- CountryChina
- Language:Chinese
-
Abstract:
Objective To explore the value of transthoracic echocardiography (TTE) to monitor and evaluate aortic insufficiency (AI) within one year after the implantation of the left ventricular assist device (LVAD). Methods We retrospectively collected and analyzed the TTE data of 12 patients who received LVAD implantation from 2018 to 2020 in our hospital. All patients were males, with an average age of 43.3±8.6 years. We analyzed temporal changes in the aortic annulus (AA), aortic sinus (AoS), ascending aorta (AAo), the severity of AI and the opening of aortic valve before operation and 1 month, 3 months, 6 months and 12 months after LVAD implantation. Results All 12 patients survived within 1 year after LVAD implantation. One patient was bridged to heart transplantation 6 months after implantation, and two patients did not receive TTE after 3 and 6 months. Compared to pre-implantation, AoS increased at 1 month after implantation (31.58±5.09 mm vs. 33.83±4.69 mm). The inner diameters of AA, AoS and AAo increased at 3, 6 and 12 months after LVAD implantation compared to pre-implantation (P<0.05), but all were within the normal range except for one patient whose AoS slightly increased before operation. After LVAD pump speed was adjusted, the opening of aortic valve improved. The severity of AI increased at 6 and 12 months after LVAD implantation compared to pre-implantation, and increased at 12 months compared to 6 months after LVAD implantation (P<0.05). Conclusion TTE can evaluate aortic regurgitation before and after LVAD implantation and monitor the optimization and adjustment of LVAD pump function, which has a positive impact on the prognosis after LVAD implantation.