Pulmonary ventilation function parameters of children aged 5-14 years in Kunming, China: a comparative analysis of measured values versus predicted values based on Zapletal equation.
- Author:
Jie YANG
1
;
Hong-Min FU
1
;
Tao-Zhen BAI
;
Fan WANG
1
;
Ou ZHANG
1
;
Shu-Dong ZHANG
1
;
Wen-Sha NIE
1
Author Information
1. Department of Respiratory and Critical Diseases, Children's Hospital of Kunming Medical University, Kunming 650032, China.
- Publication Type:Journal Article
- MeSH:
Adolescent;
Child;
Child, Preschool;
China;
Female;
Forced Expiratory Volume;
Humans;
Lung/physiology*;
Male;
Pulmonary Ventilation;
Reference Values;
Vital Capacity
- From:
Chinese Journal of Contemporary Pediatrics
2020;22(12):1313-1319
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To study the percentage of the measured values of the main pulmonary ventilation function parameters in their predicted values based on Zapletal equation among healthy children aged 5-14 years in Kunming, China, and to provide a basis for accurate judgment of pulmonary ventilation function in clinical practice.
METHODS:A total of 702 healthy children aged 5-14 years (352 boys and 350 girls) from Kunming were enrolled. The Jaeger spirometer was used to measure the nine indices:forced vital capacity (FVC), forced expiratory volume in one second (FEV1), ratio of forced expiratory volume in one second to forced vital capacity (FEV1/FVC), maximal mid-expiratory flow (MMEF), forced expiratory flow at 25% of forced vital capacity (FEF25), forced expiratory flow at 50% of forced vital capacity (FEF50), forced expiratory flow at 75% of forced vital capacity (FEF75), peak expiratory flow (PEF), and maximal voluntary ventilation (MVV). The values obtained from the Zapletal equation of predicted values provided by the spirometer were used as the predicted values of children, and the percentage of measured values in predicted values was calculated.
RESULTS:In the 702 children, the percentages of the measured values of the main pulmonary ventilation function parameters PEF, FVC, FEV1, FEV1/FVC, and MVV in their predicted values fluctuated from 102% to 114%, 94% to 108%, 98% to 113%, 98% to 107%, and 141% to 183% respectively. As for the main airway velocity parameters, the percentages of the measured values of FEF25, FEF50, FEF75, and MMEF in their predicted values fluctuated from 98% to 116%, 85% to 102%, 71% to 98%, and 83% to 100% respectively. The percentages of the measured values of PEF, FVC, FEV1, FEV1/FVC, MVV, FEF25, FEF50, FEF75, and MMEF in their predicted values had the lower limits of normal of 88.2%, 88.4%, 92.0%, 94.4%, 118.5%, 82.9%, 70.0%, 62.1%, and 70.1% respectively.
CONCLUSIONS:There are differences between pulmonary ventilation function parameter levels and normal values provided by Zapletal equation in healthy children aged 5-14 years in Kunming. As for the pulmonary ventilation function parameters of PEF, FVC, FEV, FEV1/FVC, MVV, FEF25, FEF50, FEF75, and MMEF in these children, the lower limits of normal of measured values in predicted values may be determined as 88.2%, 88.4%, 92.0%, 94.4%, 118.5%, 82.9%, 70.0%, 62.1%, and 70.1% respectively.