HPLC Fingerprint Analysis of Liposoluble and Water-soluble Fractions of Xiaojinwan
10.13422/j.cnki.syfjx.20201052
- VernacularTitle:小金丸脂溶性和水溶性部位的HPLC指纹图谱分析
- Author:
Bi FENG
1
;
Jiao SONG
1
;
Zhi-min CI
1
;
Bo CAO
1
;
Hong XU
2
;
Xiao-juan DU
2
;
Jun-zhi LIN
3
;
Ding-kun ZHANG
1
;
Li HAN
1
;
Run-chun XU
1
Author Information
1. School of Pharmacy,Chengdu University of Traditional Chinese Medicine (TCM), Chengdu 611137,China
2. Chengdu Yonkon Pharmacy Co. Ltd.,Chengdu 610041,China
3. Teaching Hospital of Chengdu University of TCM,Chengdu 610075,China
- Publication Type:Research Article
- Keywords:
Xiaojinwan;
liposoluble fraction;
water-soluble fraction;
fingerprint;
similarity;
principal component analysis (PCA);
high performance liquid chromatography (HPLC)
- From:
Chinese Journal of Experimental Traditional Medical Formulae
2020;26(18):139-144
- CountryChina
- Language:Chinese
-
Abstract:
Objective:High performance liquid chromatography (HPLC) fingerprints of liposoluble and water-soluble fractions of Xiaojinwan were established and the similarity of fingerprints was evaluated, so as to explore the quality consistency of Xiaojinwan. Method:Chromatographic separation was carried out on Welch Ultimate AQ-C18 column (4.6 mm×250 mm, 5 μm) with the mobile phase of 0.1% phosphoric acid solution (A)-acetonitrile (B) for gradient elution (liposoluble fraction of 0-5 min, 40%B; 5-10 min, 40%-50%B; 10-20 min, 50%-60%B; 20-30 min, 60%-65%B; 30-40 min, 65%-70%B; 40-50 min, 70%-80%B; 50-60 min, 80%-90%B; 60-65 min, 90%-95%B; 65-75 min, 95%-100%B; 75-80 min, 100%B; water-soluble fraction of 0-20 min, 2%-5%B; 20-30 min, 5%-10%B; 30-37 min, 10%-20%B; 37-45 min, 20%-30%B; 45-50 min, 30%-40%B; 50-58 min, 40%B), the flow rate was 1 mL·min-1, the column temperature was 30 ℃. The detection wavelengths of the liposoluble and water-soluble fractions were 202, 250 nm, and their injection volumes were 10, 20 μL, respectively. A total of 30 batches of Xiaojinwan from five manufacturers were detected by HPLC, the chromatographic peaks of each part were analyzed by principal component analysis (PCA) and identified. Result:A total of 55 chromatographic peaks were detected in the fingerprints, and the similarity of fingerprint of 30 batches of Xiaojinwan was quite different. The relative standard deviations (RSDs) of fingerprint similarity of liposoluble and water-soluble fractions of Xiaojinwan were 21.5% and 32.8%, respectively. There were significant differences in the quality of samples from different manufacturers and the same manufacturer, and the chemical consistency evaluation results were dominated by liposoluble fraction, and the main reason for the chemical difference of this preparation was the composition of Liquidambaris Resina. Conclusion:The quality consistency of Xiaojinwan is poor. The establishment of two-fraction fingerprint provides a new idea for the overall quality evaluation and control of Xiaojinwan, and can provide a reference for the quality consistency evaluation of traditional pills.