Comparative study of conventional endoscopy, endoscopic ultrasonography and narrow-band imaging combined with magnifying endoscopy in evaluating the depth of invasion of early gastric cardiac cancer
10.3760/cma.j.cn311367-20200214-00055
- VernacularTitle:白光内镜、超声内镜和窄带成像结合放大内镜评估早期贲门癌浸润深度的比较研究
- Author:
Wanyin DENG
1
;
Ying LIN
;
Xiaolu LIN
;
Guowei WANG
;
Xianbin GUO
;
Jinhui ZHENG
Author Information
1. 福建省立医院消化内镜中心,福州 350001
- From:
Chinese Journal of Digestion
2020;40(10):680-685
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the accuracy of white light conventional endoscopy (CE), endoscopic ultrasonography (EUS) and narrow-band imaging with magnifying endoscopy (ME-NBI) in evaluating the invasion depth of early gastric cardiac cancer, and to explore the diagnostic strategy of preoperative evaluation of invasive depth of early gastric cardiac cancer.Methods:From January 2016 to June 2019, the endoscopic images of 135 patients with early gastric cardiac cancer confirmed by pathology in Fujian Provincial Hospital were retrospectively analyzed. Intramucosal carcinoma (M) and superficial submucosal invasive carcinoma (SM1) were classified as M-SM1 cancer and compared with deep submucosal invasive cancer. The pathological diagnosis after operation was used as gold standard. The accuracy of CE, EUS, ME-NBI and the combination of them in determining the invasion depth of early gastric cardiac cancer was evaluated. Kappa test was performed for consistency test. Kappa value < 0.2 was considered as poor consistency, 0.2 to 0.4 as general consistency, more than 0.4 to 0.6 as medium consistency, more than 0.6 to 0.8 as high consistency, and 0.8 to 1.0 as close to full consistency. Results:The data of 73 patients with early gastric cardiac cancer were enrolled in this study. According to the pathological results after operation, 47 cases were M-SM1 cancer and 26 cases were deep submucosal invasive cancer. The diagnostic accuracy of CE, EUS, ME-NBI and the combination of them before operation were 79.5% (58/73), 72.6% (53/73), 65.7% (48/73) and 87.7% (64/73), respectively. The results of consistency test indicated that the consistency of CE diagnosis and pathological results after operation was medium ( Kappa=0.540, P<0.01), that of EUS and pathological results after operation was general ( Kappa=0.346, P=0.002), that of ME-NBI and pathological results after operation was poor ( Kappa=0.175, P=0.108), while that of the combination of them and pathological results after operation was high ( Kappa=0.724, P<0.01). Conclusions:Compared with single examination method, the combination of CE, EUS and ME-NBI is more accurate in evaluating the invasive depth of early gastric cardiac cancer.