Application of fetal heart quantitative technique in evaluation of fetal heart morphology and function
10.3760/cma.j.cn114798-20191022-00779
- VernacularTitle:胎心定量技术评价胎儿心脏形态及功能变化的初步研究
- Author:
Jia HUANG
1
;
Yuguo ZHANG
;
Hua SHI
;
Qian CHEN
;
Jiaqi HU
;
Juan HE
Author Information
1. 武汉大学人民医院妇产超声科 430060
- From:
Chinese Journal of General Practitioners
2020;19(6):541-544
- CountryChina
- Language:Chinese
-
Abstract:
Forty eight singleton normal fetuses underwent two-dimensional echocardiography with fetal heart quantitative technique (fetal HQ) in People′s Hospital of Wuhan University on September 2019. Fetal ventricular intima was successfully tracked by fetal HQ software in 45 cases; the length, transverse width, area, and global spherical index(GSI) of four-chamber view were measured with fetal HQ, meanwhile the dynamic tracking curve of ventricular intima was obtained. The left (right) ventricular global strain (GS), fetal area change (FAC), left ventricular ejection fraction (EF) and 24 segment end diastolic diameter (ED), short-axis shortening (FS), spherical index (SI) were calculated. Fetal heart shape and size and cardiac function parameters, as well as z-score of each parameter after adjustment for gestational age, were obtained successfully. The length, transverse width and area were linearly correlated with gestational age, while other parameters and their Z scores were not significantly correlated with gestational age. Z score of measured values of each parameter fell within the normal range of -2