Detection of donor kidney carrier carbapenem-resistant Klebsiella pneumoniae using combined GeneXpert and culture of kidney perfusion fluid
10.3760/cma.j.cn421203-20200309-00061
- VernacularTitle:GeneXpert联合灌洗液培养在肾移植供者来源CRKP检测中的临床应用
- Author:
Dawei LI
1
;
Fang GAO
;
Ruoyang CHEN
;
Jiajin WU
;
Liang YING
;
Chen ZHONG
;
Feng QIU
;
Xiaodong YUAN
;
Ming ZHANG
Author Information
1. 上海交通大学医学院附属仁济医院泌尿外科 200012
- From:
Chinese Journal of Organ Transplantation
2020;41(4):232-236
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explorer the optimal method of detecting donor kidney carrier carbapenem-resistant Klebsiella pneumoniae (CRKP).Methods:Clinical data were retrospectively analyzed for 1120 donation-after-circulatory-death (DCD) kidneys and bacterial detection of kidney perfusion fluid was performed from January 2015 to January 2019. A total of 1120 kidney perfusion fluid samples were collected with sterile tubes and submitted for culturing. And 451 specimens were delivered in sterile tubes and blood culture bottles simultaneously And 729 specimens assayed for carbapenemase genes with GeneXpert.Results:Among 1120 kidneys, CRKP was confirmed in 21 grafts with an infection rate of 1.87 %. The detection of carbapenemase genes with Genexpert showed that KPC was positive for 9/16 CRKP positive grafts. Sensitivity, specificity, false-positive rate, false-negative rate and ROC-AUC were calculated at 56.3 %, 100 %, 0, 43.7 % and 0.781 respectively. And 11 specimens delivered with sterile tube were culture positive for CRKP. Sensitivity, specificity, false-positive rate, false-negative rate and ROC-AUC were calculated at 52.3 %, 100 %, 0, 47.6 % and 0.762 respectively. Among 451 perfusion fluid samples collected with anaerobic blood culture bottle, 15 samples had a positive culture for CRKP. Sensitivity, specificity, false-positive rate, false-negative rate and ROC-AUC were calculated at 100 %, 100 %, 0, 0 and 1 respectively. In terms to anaerobic blood culture bottle, sensitivity, specificity, false-positive rate, false-negative rate and ROC-AUC were calculated at 60 %, 100 %, 0 , 40 % and 0.80 respectively.Conclusions:Genexpert assay is suitable for rapid and convenient detection of carbapenemase genes using kidney perfusion fluid. Culturing perfusion fluid samples collected with anaerobic blood culture bottle is clinically valuable diagnostic tool of CRKP. A combination of both methods is worthy of clinical promotion and application diagnosis of donor kidney derived CRKP in terms of greater accuracy and timeliness.