18F-FDG PET/CT images quality and its impact factors in diabetic and non-diabetic patients with coronary artery disease
10.3760/cma.j.cn321828-20191012-00231
- VernacularTitle:合并和不合并糖尿病的冠心病患者 18F-FDG PET/CT心肌代谢图像质量及其影响因素
- Author:
Ziwei ZHU
1
;
Zhi CHANG
;
Xiaopeng SHI
;
Xiaofen XIE
;
Quan LI
;
Jingjing MENG
;
Yingfei PI
;
Xue CAO
;
Jian JIAO
;
Xia LU
;
Yingsheng ZHOU
;
Xiaoli ZHANG
Author Information
1. 首都医科大学附属北京安贞医院核医学科、分子影像中心 100029
- From:
Chinese Journal of Nuclear Medicine and Molecular Imaging
2020;40(5):281-287
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the image quality (IQ) of 18F-fluorodeoxyglucose (FDG) PET/CT imaging and identify its influenfial factors in diabetes mellitus (DM) and non-DM patients with coronary artery disease (CAD). Methods:A total of 196 consecutive CAD patients (174 males, 22 females, 68 DM; age: (57±10) years) in Beijing Anzhen Hospital between June 2016 and February 2018 were retrospectively analyzed. All patients underwent 18F-FDG myocardial PET/CT imaging. The standardized fasting+ oral glucose loading (OGL) and intravenously injection of insulin protocol was performed. According to the FDG uptake by myocardium, background activity in blood and other visceral organ nearby the heart, the IQ was visually evaluated and scored by 0-4. Zero-two was considered as good IQ, 3-4 was regarded as poor IQ. Patients were divided into three groups: group 1 (non-DM+ good IQ), group 2 (DM+ good IQ), group 3 (DM+ poor IQ). Factors which may affect IQ were analyzed, which including OGL, the injection dose of insulin, fasting blood glucose (FBG), peak blood glucose (PBG), blood glucose (BG) level at 18F-FDG injection (BG injnection), BG increasing rate ((PBG-FBG)/FBG, %), and BG decreasing rate ((PBG-BG injection)/PBG, %). One-way analysis of variance, Spearman correlation analysis and logistic regression analysis were used for data analysis. Results:There were significant differences ( F values: 13.074-38.371, all P<0.05) of FBG, PBG, OGL, BG decreasing rate and the injection dose of insulin among group 1 ( n=132, 67.3%), group 2 ( n=53, 27.1%), group 3 ( n=11, 5.6%). All those parameters, except for OGL, were positively correlated with FDG PET/CT IQ ( r s values: 0.142-0.262, all P<0.05). OGL was negatively correlated with IQ ( r s=-0.324, P<0.05). Logistic regression analysis showed that FBG (odds ratio ( OR)=0.687, 95% CI: 0.633-0.746), PBG( OR=0.786, 95% CI: 0.746~0.829), BG injection( OR=0.631, 95% CI: 0.595-0.716), OGL( OR=0.897, 95% CI: 0.873-0.922), the injection dose of insulin( OR=0.680, 95% CI: 0.618-0.748) were predictive factors (all P<0.01) for good IQ in all patients. For DM patients, OGL was the only predictive factor for good IQ( OR =0.940, 95% CI: 0.904-0.960; P<0.01). Conclusions:FBG, PBG, BG injection, OGL, the injection dose of insulin can predict IQ for all patients with CAD. For DM patients with CAD, OGL is the only predictive factor for good IQ. A good IQ of 18F-FDG PET/CT could be obtained in majority of CAD patients, with the standardized fasting + OGL and intravenously injection of insulin protocol and adjust according to the personal status, and prevent the hypoglycemia from happening.