Analysis the causes of endplate injury in oblique lateral interbody fusion
10.3760/cma.j.cn121113-20200427-00296
- VernacularTitle:腰椎斜外侧椎间融合术中终板损伤的原因分析
- Author:
Zhongyou ZENG
1
;
Xiangqian FANG
;
Weihu MA
;
Dengwei HE
;
Wenfei NI
;
Wei YU
;
Xin ZHAO
;
Yongxin SONG
;
Jianqiao ZHANG
;
Shiyang FAN
;
Fei PEI
;
Sunwu FAN
Author Information
1. 武警海警总队医院骨二科,嘉兴 314000
- From:
Chinese Journal of Orthopaedics
2020;40(17):1144-1154
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To investigate the characteristics and causes of endplate injury in the oblique lateral interbody fusion for the treatment of lumbar diseases, and summarize the precaution of endplate injury.Methods:Thirty-five cases of endplate injury were observed, which were originally treated with oblique lateral interbody fusion with or without pedicle screw fixation from October 2014 to December 2017. There were 7 males and 28 females, and the age ranged from 51 to 78 years old (averagely 62.8±8.13 years). There were 2 cases of lumbar disc degeneration, 10 cases of lumbar canal stenosis, 17 cases of lumbar degenerative spondylolisthesis, 2 cases of lumbar spondylolysis with or without spondylolisthesis, and 4 cases of lumbar degenerative scoliosis. Lesion sites contained L 3,4 in 2 cases, L 4,5 in 21 cases, L 2-4 in 3 cases, L 3-5 in 4 cases, L 2-5 in 3 cases and L 1-5 in 2 cases. Preoperative bone mineral density examination revealed there were 7 cases of T>-1 SD, 24 cases of -2.5 SD