Application of three dimensional balanced steady state free precession cine MRI in evaluation of cardiac function in children with repaired tetralogy of Fallot
10.3760/cma.j.cn112149-20190619-00500
- VernacularTitle:心脏MRI三维平衡稳态自由进动电影成像在儿童法洛四联症术后心功能评价中的可行性研究
- Author:
Yafeng PENG
1
;
Liwei HU
;
Aimin SUN
;
Qian WANG
;
Rongzhen OUYANG
;
Chen GUO
;
Xiaofen YAO
;
Yumin ZHONG
Author Information
1. 国家儿童医学中心(上海) 上海交通大学医学院附属上海儿童医学中心放射科 200127
- From:
Chinese Journal of Radiology
2020;54(7):649-654
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the feasibility of cardiac MRI three dimensional (3D) balanced steady state free precession (b-SSFP) cine imaging in evaluating cardiac function in children with repaired tetralogy of Fallot (TOF).Methods:Thirty children with repaired TOF underwent cardiac MRI examination at Shanghai Children′s Medical Cent er Affiliated to Shanghai Jiao Tong University School of Medicine, were retrospectively collected from April 2018 to October 2019. From June 2017 to August 2018, 10 healthy children were enrolled. Cardiac images of subjects were obtained using both two dimensional (2D) b-SSFP and 3D b-SSFP cardiac cine MRI and the total acquisition time was recorded. The image quality was scored using a 5-point scale, with a score≥3 as diagnostic image quality. The left and right ventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), cardiac output (CO), and cardiac index (CI) were measured. The left and right ventricle parameters were compared using paired ttest or Wilcoxon test. The Pearson correlation or Spearman correlation analysis were used to evluate the correlation between the parameters measured with the 2 methods. Results:The acquisition time of 2D b-SSFP images was (426.5±13.0) s, and the total time of 3D b-SSFP images was (24.7±2.5) s. The 2D b-SSFP image quality score was better than 3D b-SSFP, and the differences were statistically significant (TOF patients: Z=-3.879, P<0.001; volunteers: Z=-2.646, P=0.003). All 2D and 3D b-SSFP image quality scores were ≥ 3 points, which can be used for clinical diagnosis. There were no statistically significant differences in cardiac function parameters between two series measurements in both TOF patients and volunteers ( P>0.05). For TOF patients, the left ventricular EDV, ESV, SV, EF, CO and right ventricular EDV, ESV, and SV showed highly positive correlation ( r>0.8, P<0.05). For volunteers, the left ventricular EDV, ESV, SV and right ventricular EDV and SV showed highly positive correlation ( r>0.8, P<0.05). Conclusion:Compared with the 2D b-SSFP sequence, 3D b-SSFP sequence with fairy good image quality can meet the diagnostic requirement and can accurately measure the cardiac function with shorter acquisition time. The 3D b-SSFP has a good application prospect in pediatric cardiac MRI.