A feasibility study on calculating individualized scheme of dose of iodine contrast medium in enhanced abdominal CT imaging based on liver volume measurement
10.3760/cma.j.cn112149-20190826-00719
- VernacularTitle:基于肝脏体积测量计算腹部CT增强扫描碘对比剂剂量个体化方案的可行性
- Author:
Wei SONG
1
;
Liang LYU
;
Xingli LIU
;
Gang WANG
;
Zhi LI
;
Jingsong YANG
;
Zhihua WANG
Author Information
1. 云南省第一人民医院昆明理工大学附属昆华医院放射科 650031
- From:
Chinese Journal of Radiology
2020;54(5):403-407
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the feasibility and value of individualized scheme of dose of iodine contrast medium in enhanced abdominal CT imaging based on liver volume (LV) measurement.Methods:The examination data and technical parameters of 64 patients, who underwent multi-phase dynamic enhanced abdominal CT imaging from February to September 2019 at First People's Hospital of Yunnan Province were retrospectively analyzed. The density of liver on CT pre-contrast images and post-contrast images, LV and average iodine content in the liver (AII) of all subjects were measured. The difference of liver density (ΔHU), total iodine dose of contrast agent injected (IM) and total intrahepatic iodine (TII) were calculated. Pearson correlation analysis was performed to evaluate the association between AII and ΔHU, as well as IM and TII. The difference between the injection volume of contrast agent predicted by the formula and the actual injection volume of contrast agent was tested by paired t test. Results:The ΔHU and AII showed highly positive correlation ( r=0.926, P<0.05). The regression equation was Y AII=0.034X ΔHU+0.296. The TII showed significantly positive correlation with the IM ( r=0.759, P<0.05), and the regression equation was Y IM=3.649X TII+16 486.754. With the liver enhancement ΔHU=50 HU as a reference, the individually dose of contrast medium injection could be deducted based on LV, with Y IM=7.225X LV+ 16 486.754. This formula was introduced into all the subjects to calculate the predicted value of contrast agent application, and the calculated injection volume of contrast agent was (64.27± 4.92) ml. Paired t test was conducted to compare the predicted injection volume of contrast agent with the actual injection volume of contrast agent, and the difference was statistically significant ( t= 6.009, P<0.05). Conclusion:The feasibility of calculating individualized scheme of contrast agent based on LV in enhanced abdominal imaging is verified. This method can be used to predict the enhancement level of liver and to reduce the dosage of iodine contrast agent.