Clinical value of three-dimensional ultrasound imaging in the localization and shaping of intrauterine contraceptive device
10.3760/cma.j.issn.1008-6706.2020.19.009
- VernacularTitle:三维超声成像技术用于宫内节育器定位、定型的诊断价值分析
- Author:
Yiqing WANG
1
;
Jing XING
;
Ning DING
;
Yongmei LI
Author Information
1. 浙江省新安国际医院超声科,嘉兴 314031
- From:
Chinese Journal of Primary Medicine and Pharmacy
2020;27(19):2344-2347
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the clinical value of three-dimensional ultrasound imaging in the localization and shaping of intrauterine contraceptive device.Methods:A total of 46 patients with abnormal intrauterine contraceptive device positions who admitted to Xin'an International Hospital from May 2018 to May 2019 were selected.All patients were examined by two-dimensional ultrasound and three-dimensional ultrasound, and the results were compared with the surgical results of the patients.The application value of three-dimensional ultrasound in the localization and shaping of intrauterine contraceptive device was analyzed.Results:By surgery pathology diagnosed with synthetic in palace in 2 cases, synthetic down in 29 cases, synthetic part or security in 15 cases.The two-dimensional ultrasonic diagnosis of patients with synthetic in the palace in 2 cases, synthetic down in 30 cases, synthetic part or security embedded in 11 cases, abnormal suspicious uncertain in 3 cases, 3 cases of missed diagnosis, 1 case of misdiagnosis.The three-dimensional ultrasound diagnosis in patients with synthetic in the palace in 2 cases, synthetic down in 29 cases, synthetic part or security embedded in 14 cases, abnormal suspicious uncertain in 1 case, no misdiagnosis, missed diagnosis in 1 case, pure synthetic down patients can be removed under hysteroscopy.Patients with IUD outside the uterus were removed laparoscopically without IUD rupture or residual fragments.And synthetic guided by hysteroscopy in patients with incarcerated during extraction, 3 cases of synthetic fracture or residual fragments occurring and compared with synthetic down the difference was statistically significant (χ 2=4.982, P<0.05), compared with the synthetic located outside the uterus, the difference was statistically significant (χ 2=4.634, P<0.05), the incidence of completely bypassed economizer fracture or residual fragments was higher than partial incarceration patients (χ 2=4.845, P<0.05). Conclusion:Three-dimensional ultrasound has higher accuracy in positioning and shaping the intrauterine contraceptive device of patients, which can guide clinicians to choose the treatment program.