Shear wave elastography in quantitative evaluation of penile corpus cavernosum hardness
10.13929/j.1003-3289.201811086
- VernacularTitle: 剪切波弹性成像定量评价阴茎海绵体硬度
- Author:
Hao CHENG
1
Author Information
1. Department of Ultrasound Medicine, The First Affiliated Hospital of Xi'an Jiaotong University
- Publication Type:Journal Article
- Keywords:
Corpus cavernosum;
Penis;
Ultrasonography
- From:
Chinese Journal of Medical Imaging Technology
2019;35(6):891-894
- CountryChina
- Language:Chinese
-
Abstract:
Objective: To explore of value of real-time shear wave elastography (SWE) in quantitative evaluation of corpus cavernosum hardness. Methods: Totally 150 healthy volunteers were divided into 5-12 years old group, 13-18 years old group, 19-30 years old group, 31-50 years old group and 51-70 years old group. Young's modulus of the corpus cavernosum was measured quantitatively with SWE imaging function. Results: The hardness of penile cavernosum increased with the increase of age. Young's modulus was (9.05±0.85)kPa in 5-12 years old group, (11.01±1.34)kPa in 13-18 years old group, (12.03±0.85)kPa in 19-30 years old group, (16.33±1.56)kPa in 31-50 years old group and (24.46±1.81)kPa in 51-70 years old group. Conclusion: SWE can be used for quantitative measurement of Young's modulus of corpus cavernosum, which is noninvasive, simple, safe and has important clinical application value.