Development and clinical application of a new type of anatomical locking plate for sternoclavicular joint fracture and dislocation
10.7507/1002-1892.201707081
- Author:
Yuanlin SUN
1
Author Information
1. Department of Bone and Joint Surgery, Affiliated Hospital of Southwest Medical University
- Publication Type:Journal Article
- Keywords:
internal fixation;
new type of anatomical locking plate;
Sternoclavicular joint fracture and dislocation
- From:
Chinese Journal of Reparative and Reconstructive Surgery
2018;32(3):316-321
- CountryChina
- Language:Chinese
-
Abstract:
Methods: A new type of anatomical locking plate for sternoclavicular joint was developed, which accorded with the anatomical features and biomechanical characteristics of Chinese sternoclavicular joint. By adopting the method of clinical randomized controlled study, 32 patients with the sternoclavicular joint fracture and dislocation who met the selection criteria between June 2008 and May 2015 were randomly divided into groups A and B ( n=16), and the patients were treated with new anatomic locking plate and distal radial T locking plate internal fixation, respectively. There was no significant difference between 2 groups in gender, age, injured side, body mass index, cause of injury, type of injury, the time from injury to operation, and preoperative Rockwood grading score ( P>0.05). The operation time, intraoperative blood loss, incision length, hospitalization time, and postoperative complications in 2 groups were recorded, and the effectiveness was evaluated by Rockwood grading score.