Effects of Fresh Gas Flow Rate on the Ratio of Expired to Inspired Anesthetic Concentration.
10.4097/kjae.2006.50.6.629
- Author:
Won Jung SHIN
1
;
Kyu Taek CHOI
Author Information
1. Department of Anesthesiology and Pain Medicine, Asan Medical Center, College of Medicine, University of Ulsan, Seoul, Korea. qtek@amc.seoul.kr
- Publication Type:Original Article ; Randomized Controlled Trial
- Keywords:
anesthetic uptake;
delivered concentration;
fresh gas flow rate;
inspired concentration;
volatile anesthetics
- MeSH:
Anesthetics;
Humans;
Isoflurane;
Thyroidectomy
- From:Korean Journal of Anesthesiology
2006;50(6):629-636
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
BACKGROUND: One way to make rapid increase in alveolar anesthetic concentration includes using high fresh gas flow rates. Fresh gas flow rates should be increased to compensate the amount of uptake either. This study was performed to elucidate optimal fresh gas flow rates for rapid induction by comparison of changes of ratio of expired to inspired concentration. METHODS: The study population was composed of 107 patients undergoing thyroidectomy. Patients were randomly allocated to one of three groups who received desflurane or sevoflurane or isoflurane. Each group was randomly subdivided into three groups who received one of the fresh gas flow rate: 2, 5 or 10 L/min. Inspired anesthetic concentration (Fi) and expiratory anesthetic concentration (Fe), delivered concentration (FD) were recorded. RESULTS: With same fresh gas flow rates, there were significant differences between Fe/Fi of desflurane, sevoflurane, isoflurane. With same anesthetics, Fe/Fi of desflurane and sevoflurane were not influenced by fresh gas flow rates. But Fe/Fi of isoflurane at 2 L/min was significantly lower than 5 L/min and 10 L/min. Fi/FD of desflurane at 10 L/min did not differ from sevoflurane. At 2 L/min and 5 L/min, Fi/FD of desflurane was highest and then sevofluane, isoflurane in that order. CONCLUSIONS: Because rates of Fe/Fi of desflurane and sevoflurane were not influenced by fresh gas flow rates, 2 L/min of fresh gas flow rates could be selected. However, considering the wash-in time in circuit, optimal choice of fresh gas flow rate for desflurane and sevoflurane could be 5 L/min, that of isoflurane be 10 L/min.