Simultaneous determination of 13 bioactive components in Jiawei Zuojin Pill by HPLC-MS/MS
10.7501/j.issn.0253-2670.2020.14.012
- VernacularTitle: 液质联用法同时测定加味左金丸中13种有效成分
- Author:
Hui-Peng CHEN
1
Author Information
1. Beijing University of Chinese Medicine Shenzhen Hospital (Longgang)
- Publication Type:Journal Article
- Keywords:
Baicalin;
Berberine;
Costunolide;
Evodiamine;
Ferulic acid;
Hesperidin;
HPLC-MS/MS;
Jiawei Zuojin Pill;
Naringin;
Paeoniflorin;
Palmatine;
Rutecarpine;
Saikosaponin a;
Saikosaponin d;
Tetrahydropalmatine
- From:
Chinese Traditional and Herbal Drugs
2020;51(14):3693-3699
- CountryChina
- Language:Chinese
-
Abstract:
Objective: To develop and validate an high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-ESI-MS/MS) method for simultaneously qualitative and quantitative determination of 13 major bioactive components (ferulic acid, costunolide, baicalin, paeoniflorin, tetrahydropalmatine, rutecarpine, berberine, palmatine, evodiamine, naringin, hesperidin, saikosaponin a, and saikosaponin d) in Jiawei Zuojin Pills (JZP). Methods: The chromatographic separation was performed on a Thermo Syncronis C18 column (100 mm × 4.6 mm, 3.0 μm) with a gradient elution of methanol and 0.02 mol/L ammonium acetate in water at a flow rate of 0.35 mL/min, and the injection volume was 10 μL. The 13 major bioactive components were detected using an electrospray ionization source in ESI+ and ESI- ionization mode, quantified by multiple reaction monitor (MRM) scanning at the same time. Results: The linear ranges of ferulic acid, costunolide, baicalin, paeoniflorin, tetrahydropalmatine, rutecarpine, berberine, palmatine, evodiamine, naringin, hesperidin, saikosaponin a and saikosaponin d were 2-80 μg/mL (r = 0.999 2), 0.5-20.0 μg/mL (r = 0.999 1), 3.5-140.0 μg/mL (r = 0.999 8), 1-40 μg/mL (r = 0.999 2), 0.3-12.0 μg/mL (r = 0.999 1), 1-40 μg/mL (r = 0.999 2), 3-120 μg/mL (r = 0.999 7), 2.5-100.0 μg/mL (r = 0.999 5), 0.5-20.0 μg/mL (r = 0.999 3), 0.5-20.0 μg/mL (r = 0.999 1), 1-40 μg/mL (r = 0.999 1), 0.3-12.0 μg/mL (r = 0.999 2), 0.3-12.0 μg/mL (r = 0.999 2), and the average recoveries were 99.5% (RSD = 4.11%), 98.9% (RSD = 4.88%), 100.2% (RSD = 1.08%), 99.2% (RSD = 3.23%), 99.5% (RSD = 4.13%), 99.7% (RSD = 3.23%), 98.6% (RSD = 2.78%), 99.9% (RSD = 3.12%), 101.3% (RSD = 4.53%), 98.7% (RSD = 3.43%), 99.8% (RSD = 3.58%), 97.9% (RSD = 5.22%), and 101.3% (RSD = 5.13%), respectively. The contents of 12 batches of the 13 major bioactive components were 0.324-0.383, 0.051-0.072, 3.225-3.466, 0.154-0.198, 0.015-0.062, 0.144-0.199, 2.145-2.982, 0.441-0.953, 0.032-0.099, 0.062-0.089, 0.111-0.178, 0.012-0.065, 0.011-0.069 mg/g, respectively. Conclusion: The developed method is simple, specific, and sensitive, and it can be applied for the determination of 13 major bioactive components and the quality control of JZP.