Annual Report of the Korean Association of External Quality Assessment Service on Transfusion Medicine (2019)
10.15263/jlmqa.2020.42.3.112
- Author:
John Jeongseok YANG
1
;
Jin Seok KIM
;
Young Ae LIM
;
Hyungsuk KIM
;
Dae-Hyun KO
Author Information
1. Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
- Publication Type:Report On Proficiency Testing
- From:Journal of Laboratory Medicine and Quality Assurance
2020;42(3):112-120
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
This report summarizes the 2019 survey results of the external quality assessment (EQA) scheme for the Transfusion Medicine Program (TMP) in Korea. Proficiency testing materials were prepared at the Asan Medical Center for the biannual distribution to participating laboratories. The average accuracy rates and number of participants (in parenthesis) for ten survey items were as follows: ABO typing, 99.4%–99.9% (N=875); RhD typing, 99.8%–100% (N=864); crossmatching, 90.8%–99.6% (N=760); ABO subtyping, 98.2% and 100% (N=58); Rh CcEe antigen testing, both 100% (N=55); weak D test, 97.9%–100% (N=232); antibody screening, 99.7%– 100% (N=316); direct antiglobulin test (DAT) using a polyspecific reagent, 99.6%–100% (N=273); DAT using an immunoglobulin-G monospecific reagent, both 100.0% (N=67); DAT using a C3d monospecific reagent, 95.6%–98.5% (N=67); antibody identification, 87.9%–99.2% (N=132); and ABO Ab titration, 85.7%–100% (N=134). The number of participants showed an average increase of 14% across the ten survey items, with the ABO antibody titration showing the highest increase at 83.6%. While results were generally excellent, antibody identification and ABO antibody titration results showed room for improvement. The 2019 EQA scheme for TMP has contributed to the improvement and maintenance of the participating laboratories to the program.