The Test-Retest Reliability of Subjective Visual Horizontal Testing:Comparisons between Solid and Dotted Line Images
- Author:
Mohd Normani ZAKARIA
1
;
Nor Haniza Abdul WAHAT
;
Zuraida ZAINUN
;
Nurul Syarida Mohd SAKERI
;
Rosdan SALIM
Author Information
- Publication Type:BRIEF COMMUNICATION
- From:Journal of Audiology & Otology 2020;24(2):107-111
- CountryRepublic of Korea
- Language:English
- Abstract: The present study aimed to determine the test-retest reliability of subjective visual horizontal(SVH) testing when tested with solid and dotted line images. In this repeated measures study,36 healthy young Malaysian adults (mean age=23.3±2.3 years, 17 males and 19 females)were enrolled. All of them were healthy and had no hearing, vestibular, balance, or vision problems.The SVH angles were recorded from each participant in an upright body position using acomputerized device. They were asked to report their horizontality perception for solid and dottedline images (in the presence of a static black background). After 1 week, the SVH procedurewas repeated. The test-retest reliability of SVH was found to be good for both solid line[intraclass correlation (ICC)=0.80] and dotted line (ICC=0.78). As revealed by Bland-Altmanplots, for each visual image, the agreements of SVH between the two sessions were within theclinically accepted criteria (±2°). The SVH testing was found to be temporally reliable, which canbe clinically beneficial. Both solid and dotted lines in the SVH testing are reliable to be usedamong young adults. J Audiol Otol 2020;24(2):107-111