Value of Head and Neck CT Angiography in the Clinical Evaluation of Intraoperative Bleeding Volume of Carotid Body Tumours.
10.3881/j.issn.1000-503X.11784
- Author:
Zhan-Zhan LI
1
;
Yan LIANG
1
;
Yong-Qiang ZHANG
1
;
Juan DU
1
;
Hao-Zhe LIU
2
;
Cheng-Wei RUAN
1
;
Yun-Lu WANG
1
;
Guang-Chao GU
3
;
Hao SUN
2
;
Yu CHEN
2
;
Zheng-Yu JIN
2
Author Information
1. CT Diagnosis Center of Sanmenxia Central Hospital Affiliated to Henan University of Science and Technology,Sanmenxia,Henan 472000,China.
2. Department of Radiology,PUMC Hospital,CAMS and PUMC,Beijing 100730,China.
3. Department of Vascular Surgery,PUMC Hospital,CAMS and PUMC,Beijing 100730,China.
- Publication Type:Journal Article
- Keywords:
CT angiography;
carotid body tumor;
intraoperative bleeding volume
- MeSH:
Carotid Body Tumor;
diagnostic imaging;
Computed Tomography Angiography;
Head;
Humans;
Neck;
Retrospective Studies
- From:
Acta Academiae Medicinae Sinicae
2020;42(4):491-496
- CountryChina
- Language:Chinese
-
Abstract:
To investigate the value of head and neck CT angiography(CTA)in the evaluation of intraoperative hemorrhage of carotid body tumours. Head and neck CTA images of 36 patients with carotid body tumours confirmed by pathology were retrospectively analyzed.Patients were divided into two groups based on the intraoperative bleeding volume:<500 ml and≥500 ml groups.The patient's age,sex,Shamblin classification,size of the lesion,number of blood supply arteries,course of the disease,plain scan,and enhanced CT value between two groups were compared and analyzed.Logistics regression equation was established based on the CTA parameters with significant differences between the two intraoperative bleeding volume groups,and combined parameter was acquired.The receiver operating characteristic curve was established based on CTA single and combined parameters. The bleeding volume during the operation of carotid body tumors was significantly correlated with the age of patients(=0.019),the maximum diameter of tumours on axial images(=0.003),the maximum upper and lower diameters(=0.004),Shamblin classification(=0.012),and number of blood supply arteries(<0.001).The area under the receiver operating characteristic curve of the number of feeding arteries,the maximum diameter of axial images,maximum upper and lower diameters,Shamblin classification,and combined parameters were 0.865,0.781,0.806,0.766,and 0.927,respectively.When the optimal critical value was 0.408,the Youden index was 0.794,and the corresponding accuracy,sensitivity,and specificity were 0.919,0.909,and 0.923,respectively. Preoperative head and neck CTA can be used to evaluate the intraoperative blood loss.Combined parameters has the best diagnostic performance compared with single parameters.