Diagnostic value of platelet count ,plasma D‐dimer , antithrombin Ⅲ levels and UACR for microvascu‐lar disease in type 2 diabetes mellitus/
10.3969/j.issn.1008-0074.2019.06.21
- VernacularTitle:血小板计数、血浆D‐二聚体,抗凝血酶Ⅲ水平与UCr比值对2型糖尿病微血管病变的诊断价值
- Author:
Peng JIANG
1
;
Fuhai ZHANG
;
Yufeng LI
;
Haicheng YUE
;
Chaomin WANG
Author Information
1. 北京友谊医院平谷医院 检验科
- Keywords:
Diabetic angiopathies;
Platelet count;
Antithrombin III
- From:
Chinese Journal of cardiovascular Rehabilitation Medicine
2019;28(6):82-85
- CountryChina
- Language:Chinese
-
Abstract:
To explore diagnostic value of platelet count (PLT) ,plasma D– dimer (D‐D) , antithrombin Ⅲ(AT‐III) levels and UACR for microvascular disease (MVD) in type 2 diabetes mellitus (T2DM).Methods : A total of 284 T2DM patients treated in our hospital were divided into no MVD group (n=144) and MVD group (n=140) according to MVD condition .Another 120 healthy people were enrolled as healthy contrrol group .Levels of PLT ,plasma D‐D and AT‐Ⅲ,unine microalbuminuria (UMA) and creatinine (UCr) and UMA/UCr ratio (UACR) were measured and compared a‐mong all groups .The diagnostic value of combined detection of PLT ,plasma D‐D and AT‐Ⅲ levels and above triple detec‐tion combined UACR for MVD in T2DM were analyzed.Results : Compared with healthy control group ,there were signif‐icant reductions in levels of PLT [ (212.34 ± 51.23)×109/L vs.(116.46 ± 46.43)×109/L vs.(98.48 ± 35.66)× 109/L] and plasma AT‐III [(103.54 ± 7.23)% vs.(99.52 ± 4.24)% vs.(75.34 ± 5.31)%] ,and significant rise in levels of plasma D‐D [ (0.31 ± 0.16) mg/L FEU vs.(0.85 ± 0.33) mg/L FEU vs.(1.08 ± 0.52) mg/L FEU] and UCr [ (3.36 ± 1.56) mmol/L vs.(4.51 ± 1.79) mmol/L vs.(12.31 ± 5.12) mmol/L] in no MVD group and MVD group . And levels of PLT and plasma AT‐III of MVD group were significantly lower than those of no MVD group ,plasma D‐D and UCr levels of MVD group were significantly higher than those of no MVD group ( P< 0.01 all).Compared with healthy control group ,no MVD group ,there were significant rise in levels of UACR [ (11.25 ± 5.02) mg/mmol vs. (10.01 ± 4.39) mg/mmol vs.(59.89 ± 16.32) mg/mmol] , UMA [ (38.25 ± 17.22) mg/mmol vs.(41.11 ± 18.53) mg/L vs.(722.32 ± 101.54) mg/L] in MVD group ,and UACR of no MVD group was significantly lower than that of health control group (P<0.05 or 0.01).Compared with single UACR detection and triple combined detection of PLT ,plasma D‐D and AT‐Ⅲ levels ,there were significant rise in sensitivity (85.51% vs.87.82% vs.90.33%) ,specificity (90.54%vs.85.32% vs.94.32%) and accuracy (82.33% vs.84.56% vs.90.21%) in triple detection combined UACR ( P=0.001 all).Conclusion :Combined detection of PLT ,plasma D‐D and AT‐Ⅲ levels with UACR are significanly superior to combined detection for screening MVD in T2DM.