Study on the consistency of the position of the brackets on the digital occlusal model and the actual position af-ter indirect bonding
10.12016/j.issn.2096-1456.2017.05.007
- Author:
WAN Xian-feng
1
;
WANG Hui-ling
2
,
3
;
LIU Zhen-huan
2
,
3
;
ZHANG Jin-cai
4
;
DUAN Pei-jia
5
;
BAO Li-na
1
Author Information
1. Department of Orthodontics, Stomatological Hospital of Southern Medical University (Guangdong Provincial Stomatological Hospital)
2. Xi&rsquo
3. an Henghui Technology Co. ltd
4. University of Chinese Academy of Sciences
5. Guangdong Xieda Stomatological Hospital
- Publication Type:Journal Article
- Keywords:
Digital dental model;
Bracket positioning;
Indirect bonding;
Transfer tray;
Orthodontics
- From:
Journal of Prevention and Treatment for Stomatological Diseases
2017;25(5):311-315
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To provide the experimental basis for the coherence of the indirect bond position by comparing the position of the bracket on the digital occlusal model and the position of the transfer to the initial plaster model.
Methods:Fifteen digitized models were selected for the brackets on the dental denture model, the brackets were transferred to the initial plaster model by indirect bond transfer trays, The line distance between each bracket position in digital dental model and initial plaster model was measured with OrthoRx software.
Results :The difference between the position of the orthodontic brackets and the position of the initial plaster model was less than 0.20 mm, and the difference was statistically significant (P < 0.05).
Conclusion :The position of the bracket on the digital occlusal model is consistent with that of the original plaster model, which provides a theoretical basis for digital indirect bonding.
- Full text:托槽在数字化牙颌模型上位置与间接粘结转移后实际位置的一致性研究.pdf