Application of digital immediate implant restoration and angle screw channel abutment in the aesthetic area:case report and literature review
10.12016/j.issn.2096-1456.2020.07.007
- Author:
WAN Haoyuan
1
;
DONG Tianzhen
1
;
DENG Manjing
1
Author Information
1. Department of Stomatology, Da Ping Hospital, Amy Military Medical University
- Publication Type:Journal Article
- Keywords:
digital immediate implant;
implant repair;
angle screw channel abutment;
preoperative evaluation;
aesthetic area;
gingival contour dimension;
gingival papilla;
aesthetic effect;
cement-retained;
screw-retained
- From:
Journal of Prevention and Treatment for Stomatological Diseases
2020;28(7):443-448
- CountryChina
- Language:Chinese
-
Abstract:
Objective : To investigate the application of digital immediate implant and angle screw channel abutment in the aesthetic area and the related influencing factors by reviewing the data of one case of immediate implant repair of the upper anterior teeth and related literature.
Methods:One case of refractory chronic apicitis of the upper anterior teeth involved immediate implantation after extraction. The digital information of the patient was obtained by CBCT and intraoral scanning. According to the information from the patients, a preoperative evaluation was performed; a treatment scheme was formulated; a minimally invasive extraction was performed; implants were placed under a digital guide plate; and temporary restoration was immediately performed. Six months after the operation, the patients underwent individualized mold removal, and angle screw channel fixation was completed. We observed the cosmetic effects and soft and hard tissue and gingival contour maintenance effects after restoration and reexamined the patients 6 months after restoration. In addition, the relevant literature was reviewed.
Results :The height of the gingival margin and gingival papilla and gingival contour of this patient were well maintained. The red and white aesthetic effect was good. There was no redness or swelling of the gingiva nor obvious changes in the soft and hard tissues around the implant 6 months after restoration, and the patient was satisfied. The results in the literature review show that a preoperative design based on CBCT and intraoral scanning data combined with digital software and a whole digital guide plate make the procedure more accurate and safer. These factors can not only avoid important anatomical structures and serious surgical complications but can also result in implantation in the best three-dimensional position. In addition, the application of digital impression technology and CAD/CAM increases the efficiency, speed, accuracy, simplicity, and comfort of oral impressions and the construction of temporary and final prostheses more precise and faster, greatly improving clinical efficiency.
Conclusion:Digital immediate implant and angle screw channel abutment is a good method to restore the aesthetics and function of missing teeth and to avoid the complications caused by adhesive residue.
- Full text:数字化即刻种植修复与角度螺丝通道基台在美学区的应用1例并文献回顾2.pdf