Design and Upgrading of Finished Infusion Label in PIVAS of Our Hospital
- VernacularTitle:我院静脉用药调配中心成品输液标签的设计升级
- Author:
Ji QIU
1
;
Aihong PAN
2
;
Tingting DENG
3
;
Rui LI
1
;
Zhangwei YANG
4
;
Fu DAI
5
Author Information
1. Dept. of Pharmacy,Hefei Binhu Hospital,Hefei 231200,China
2. Dept. of Nursing,Hefei Binhu Hospital,Hefei 231200,China
3. Dept. of Pharmaceutical Affairs,Sichuan Kelun Pharmaceutical Co.,Ltd.,Chengdu 610071,China
4. Information Section,Shanghai Fourth People’s Hospital,Shanghai 200082,China
5. First People’s Hospital of Hefei,Hefei 230061,China
- Publication Type:Journal Article
- Keywords:
PVIAS;
Finished infusion label;
Information display;
Design and upgrade;
Rational drug use
- From:
China Pharmacy
2020;31(3):368-372
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To design and upgrade the finished infusion label in P IVAS of Hefei Binhu hospital ,so as to improve the safety and effectiveness of intravenous medication. METHODS :By investigating the experience and suggestions about the use of infusion labels by pharmacists and clinical nurses in PIVAS ,taking clear ,concise,focused,rational layout ,comprehensive information as improving principle ,the infusion label was designed and upgraded. The effect of upgrading were evaluated by the recognition rate of label scanning ,scanning time and rate on label (94 701,113 759 groups,respectively),and the correct rate , time and rate of drug delivery checking in 30 days before and after upgrading ,as well as satisfaction degree ,which made among PIVAS pharmacists (30),nurses(50)and patients (49). RESULTS :The upgraded label simplified part of the content and optimized the layout structure ,removed redundant content ,focused on the patient safety information that nurses needed to pay attention to when checking ,and added the marking of infusion sequence and precautions. By changing the barcode into two-dimensional code and adding hidden display function ,more information about drugs and rational drug use related to the infusion of patients was provided. Compared with original label ,after upgrading ,the recognition rate of new label scanning increased from 99.27% to 99.96%,the scanning time reduced from 3 518.75 s/d to 2 110.10 s/d,and the scanning rate increased from 0.57 group/s to 0.95 group/s;the correct rate of drug delivery checking increased from 99.73% to 99.91%,the time of drug delivery checking decreased from 5 423.55 s/d to 4 818.85 s/d,and the speed of drug delivery checking increased from 0.36 group/s to 0.41 group/s. The satisfaction degree of pharmacists ,nurses and patients were increased from 70.00% to 93.33%,from 62.00% to 90.00%,from 20.40% to 89.80%,respectively. CONCLUSIONS:The design and upgrading of infusion labels can improve the working efficiency of staff ,and improve the quality of pharmaceutical care and nursing care , and satisfaction, promote the improvement on the safety and effectiveness of intravenous medication for patients.