Treatment of Tile B pelvic fracture by external fixator combined with limited internal fixation.
10.3969/j.issn.1672-7347.2010.06.015
- Author:
Kanghua LI
1
;
Yusheng LI
;
Renjie LI
;
Zhangyuan LIN
;
Guanghua LEI
;
Qiande LIAO
Author Information
1. Department of Orthopedic Surgery, Xiangya Hospital, China. lkh8738@sina.com
- Publication Type:Journal Article
- MeSH:
Adult;
External Fixators;
Female;
Fracture Fixation;
methods;
Fracture Fixation, Internal;
methods;
Fractures, Bone;
surgery;
Humans;
Male;
Middle Aged;
Pelvic Bones;
injuries;
surgery;
Young Adult
- From:
Journal of Central South University(Medical Sciences)
2010;35(6):630-633
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To determine the effectiveness of external fixator combined with limited internal fixation for Tile B pelvic fractures.
METHODS:Fourteen patients with Tile B pelvic fracture were treated by external fixator combined with limited internal fixation between September 2004 and June 2009.
RESULTS:All the patients were followed for 6-49 (20.2 +/- 10.2) months. According to the Matta standard, the outcome of 9 patients was excellent, 4 patients were good, while the other one patient was fair.
CONCLUSION:External fixator combined with limited internal fixation is effective for Tile B pelvic fracture. It can not only reduce the anatomic position of the pelvis, but also strengthen the stability of the pelvis as a whole. This method is less invasive and traumatic, which promotes the recovery of patients.