Color Doppler flow image of Budd-Chiari syndrome.
- Author:
Jin-Tang LIAO
1
;
Ying XIAO
;
Tie-Han HUANG
;
Rui-Zhe PAN
;
Shu-Chu WANG
;
Yuan-Jin HUANG
Author Information
1. Department of Ultrasonography, Xiangya Hospital, Central South University, Changsha 410008, China. liaojintang@hotmail.com
- Publication Type:Journal Article
- MeSH:
Adolescent;
Adult;
Budd-Chiari Syndrome;
diagnosis;
diagnostic imaging;
Female;
Hepatic Veins;
diagnostic imaging;
Humans;
Male;
Middle Aged;
Retrospective Studies;
Sensitivity and Specificity;
Ultrasonography, Doppler, Color;
methods;
Vena Cava, Inferior;
diagnostic imaging
- From:
Journal of Central South University(Medical Sciences)
2007;32(1):170-173
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:To evaluate the diagnostic value of color Doppler flow image (CDFI) for the diagnosis of Budd-Chiari syndrome (B-CS).
METHODS:CDFI findings of 35 patients with B-CS were retrospectively analyzed and compared with the findings of venography of inferior vena cava (IVC).
RESULTS:Thirty-four patients were diagnosed as B-CS by CDFI, while one patient with local tunica stenosis was misdiagnosed. The correct diagnostic rate was 97.1%. In the 34 patients, CDFI displayed stenosis or occlusion in the hepatic vein and IVC in 24 patients, IVC only in 8,and hepatic vein only in 2.