Study on the three-dimensional mapping to reduce the X-ray exposure dose of interventional doctors in radiofrequency catheter ablation of atrioventricular nodal reentry tachycardia
10.3760/cma.j.issn.1001-9391.2017.08.016
- VernacularTitle: 三维标测减少AVNRT射频消融术中术者X线受照剂量的研究
- Author:
Rui WANG
1
;
Nan ZHANG
;
Ruihua WANG
;
Jia GAO
;
Zhiqiang ZHAO
;
Yongping JIA
;
Meng SUN
Author Information
1. The First Hospital of Shanxi Medical University, Taiyuan 030001, China
- Publication Type:Journal Article
- Keywords:
Three-dimensional mapping;
Radiofrequency ablation;
Radiation, ionizing;
Tachycardia, atrioventricular nodal reentry
- From:
Chinese Journal of Industrial Hygiene and Occupational Diseases
2017;35(8):614-616
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To explore the advantage of radiofrequency catheter ablation under the three-dimensional mapping in the treatment of atrioventricular nodal reentrant tachycardia (AVNRT) in reducing the X-ray exposure dose of interventional doctors.
Methods:79 patients with AVNRT, in the first hospital of Shanxi Medical University from January 2015 to June 2016, performed to do radiofrequency catheter ablation treatment were selected, and according to the random number method were divided into two-dimensional mapping group and three-dimensional mapping group. The two-dimensional mapping group was mapped the ablation target at the X-ray, while the ablation target was mapped by CARTO 3 system in the three-dimensional mapping group. Compare the X-ray fluoroscopy time, success rate, complications rate and doctor’s X-ray exposure dose between the two groups.
Results:Compared with the two-dimensional mapping group, acute success rate and complication rate of the three dimensional mapping group were not statistically significant (P>0.05) , while the X-ray fluoroscopy time and the X-ray dose of the three-dimensional mapping group decreased significantly, the difference was statistically significant (P<0.05) .
Conclusion:Three-dimensional mapping can significantly reduce the X-ray irradiation time and interventional doctor’s X-ray exposure dose in radiofrequency catheter ablation of AVNRT patients and the potential hazards of ionizing radiation on the human body.