A pilot study of the unilateral centrifugation subjective visual vertical in healthy young people
10.3760/cma.j.issn.1673-0860.2018.11.003
- VernacularTitle: 健康青年人单边离心主观视觉垂直线测试初探
- Author:
Taisheng CHEN
1
;
Xi HAN
1
;
Qiang LIU
1
;
Shanshan LI
1
;
Chao WEN
1
;
Wei WANG
1
;
Kaixu XU
1
;
Peng LIN
1
Author Information
1. Department of Otorhinolaryngology Head and Neck Surgery, Tianjin First Center Hospital, Otorhinolaryngology Institute of Tianjin, Tianjin 300192, China
- Publication Type:Journal Article
- Keywords:
Utricle;
Vestibular function tests;
Unilateral centrifugation subjective visual vertical
- From:
Chinese Journal of Otorhinolaryngology Head and Neck Surgery
2018;53(11):811-814
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the data of unilateral centrifugation subjective visual vertical (UC-SVV) in healthy young people.To study the function of utricle.
Methods:Between Decem ber 2017 and May 2018, thirty-two healthy young volunteers were tested by static subjective visual vertical(SVV) and low velocity UC-SVV with Neuro Kinetics Inc I-portal 6.0 Video nystagmus recording system and NOTC rotating chair system.The static SVV preset angle were -15.00°, 15.00°, -20.00°, 20.00°, -12.00° and 12.00° respectively.UC-SVV test parameters: rotating chair′s peak speed was 60°/s.The shift time from the middle to the lateral position was 30 s and the displacement was 3.85 cm.The chair rotated at 60 s at left, right and middle positions.Subjects underwent SVV during this period.SPSS 17.0 software was used to analyze the data.
Results:The mean and standard deviation of static SVV deviation in 32 volunteers was 0.21°±0.17°, 95%CI (-0.14°, 0.55°). The mean and standard deviation of UC-SVV in the left, middle and right positions of the clockwise was 0.24°±0.25°, -0.10°±0.27°, -0.63°±0.26°, 95%CI(-0.26°, 0.74°), (-0.65°, 0.44°), (-1.16°, -0.10°). The mean and standard deviation of UC-SVV in the left, middle and right positions of the counter clockwise was 0.03°±0.27°, -0.11°±0.26°, -0.23°±0.26°, 95%CI(-0.52°, 0.59°), (-0.65°, 0.42°), (-0.76°, 0.30°). There was significant difference in the deviation between the left and the right side of counter clockwise rotation of UC-SVV(t=2.432, P<0.05), however, there was no significant difference in the angle of deviation between the left and right sides and the median position(t value was 0.951, -1.400, both P>0.05). There was no significant difference among each position in clockwise rotation of UC-SVV(F=0.253, P>0.05).
Conclusion:UC-SVV test with peak speed of 60°/s can cause vertical line deviation in the left and right lateral position, but the angle is small and the value of clinical application is limited.