Cardioversion efficacy of nifekalan in patients with sustained atrial fibrillation after radiofrequency ablation
10.3760/cma.j.issn.0253-3758.2019.12.004
- VernacularTitle: 尼非卡兰在心房颤动患者射频消融术后转复的疗效观察
- Author:
Fan LI
1
;
Zhen XIA
;
Jianhua YU
;
Qi CHEN
;
Jinzhu HU
;
Bo ZHU
;
Zirong XIA
;
Qianghui HUANG
;
Juxiang LI
;
Kui HONG
;
Yanqing WU
;
Xiaoshu CHENG
Author Information
1. Department of Cardiology, Second Affiliated Hospital of Nanchang University, Nanchang 330006, China
- Publication Type:Journal Article
- Keywords:
Atrial fibrillation;
Catheter ablation;
Nifekalant
- From:
Chinese Journal of Cardiology
2019;47(12):963-968
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To evaluate the efficacy and safety of nifekalan (NIF) on cardioversion in atrial fibrillation (AF) patients post radiofrequency ablation, and investigate the relevant factors related to the cardioversion efficacy of NIF.
Methods:We screened patients with sustained AF rhythm after radiofrequency ablation between November 2016 and July 2018. Participants were treated with intravenous NIF 0.4 mg/kg within 5-10 minutes after ablation. We observed the adverse reaction, and monitored the rhythm, heart rate, QT interval and QTc interval before the medication and at 5, 10, 20, 120 min after the medication. According to the drug outcome of NIF, patients were divided into conversion group and non-conversion group, related factors affecting conversion efficacy were evaluated using logistic regression analysis.
Results:(1)A total of 116 patients were enrolled in the study (63 males and 53 females, mean age was (64±18) years). Among them, 72 patients were converted to sinus rhythm, and the overall successful rate was 62.1%. There were 84 patients with persistent AF, of which 50 cases (59.2%) were restored to sinus rhythm. There were 32 patients with paroxysmal AF, 22 cases (68.8%) of them were restored to sinus rhythm. The conversion time was 1.5 to 12 (6.8±3.4)min. (2) In 116 patients, the QT interval and QTc interval were significantly longer after medication than before the drug administration (P<0.01), and peaked at about 10th min, and restored to the level before drug administration at about 120th min. (3) There were 8 cases of bradycardia (6.9%), 3 cases of frequent and short ventricular tachycardia (2.6%). (4) The duration of atrial fibrillation was shorter and left atrial diameter was smaller in the cardioversion group than in the non-cardioversion group (both P<0.05). There were no significant differences in gender, disease history, atrial fibrillation type and structural heart disease between the two groups (P>0.05). (5) Multifactorial logistic regression analysis showed that the duration of atrial fibrillation (OR=0.980, 95%CI 0.966-0.994, P=0.004) and the left atrial diameter (OR=0.888, 95%CI 0.814-0.967, P=0.007) were the factors that influence the cardioversion efficacy of NIF on atrial fibrillation post ablation.
Conclusions:The total effective rate of NIF was 62.1% in patients witrh sustained AF post radiofrequency ablation, was 68.8% in patients with paroxysmal AF. Besides, NIF has the advantage of short conversion time and few adverse reactions. Left atrium diameter and AF duration were relevant factors that influence the efficacy of NIF of cardioversion in patients with sustained AF after radiofrequency ablation.