Review of Shanghai glycohemoglobin harmonization program
10.3760/cma.j.issn.1009-8158.2020.01.003
- VernacularTitle: 上海糖化血红蛋白一致性计划回顾分析
- Author:
Beili WANG
1
;
Yiwen ZHOU
;
Jiong WU
;
Wenqi SHAO
;
Wen XU
;
Wei GUO
;
Baishen PAN
Author Information
1. Department of laboratory Medicine, Zhongshan Hospital, Fudan University, Shanghai 200032, China
- Publication Type:Journal Article
- Keywords:
Diabetes mellitus;
Glycated hemoglobin A;
Reproducibility of results
- From:
Chinese Journal of Laboratory Medicine
2020;43(1):36-43
- CountryChina
- Language:Chinese
-
Abstract:
Objective:To review the results of inter-laboratory comparisons in Shanghai glycohemoglobin harmonization program from 2010 to 2018, and to analyze the evolution of quality levels of HbA1c determination, so as to provide the reference for improving the HbA1c determination quality in China.
Methods:Retrospective analysis. The comparison data of Shanghai Glycohemoglobin Harmonization Program from 2010 to 2018 was collected. And the change trend was analyzed about hospital and determination method distribution. The judgment criteria, quarterly and annual pass rate, bias and coefficient of variation of the results of the inter-laboratory comparison were analyzed retrospectively, and the results were compared with the results of External Quality Assessment Programme carried out by the National Center for Clinical Laboratories, Shanghai Center for Clinical Laboratories and College of American Pathologists (CAP). The data in the first quarter of 2019 was collected and the imprecision, bias and sigma were calculated, which were drew in the evaluation model of sigma combined with biomedical variation parameters.
Results:The number of participating laboratories increased from 9 in Shanghai to 192 in the whole country, with an average annual growth rate of 76.6%. The quarterly comparison criteria improved from ±8% to ±6% and the passing rate of participating laboratories increased from 39.1% to nearly 90%. The maximum CV of each instrument among laboratories decreased from 14.3% to 4.8%. In the first quarter of 2019, nearly 60% of the laboratories met 6σcriteria and more than 95% of the laboratories met the "standard criteria" in the model of biological variation parameters.
Conclusion:Shanghai Glycohemoglobin harmonization program has improved the harmonization of HbA1c test results among the participating laboratories.