Adjustment of automated peritoneal dialysis prescription based on volume management
10.3760/cma.j.issn.1671-7368.2020.01.017
- VernacularTitle: 基于容量管理自动化腹膜透析处方的调整
- Author:
Yixin CHEN
1
;
Meng LI
;
Qun LUO
Author Information
1. Department of Nephrology, Huamei Hospital, University of Chinese Academy of Sciences, Ningbo 315010, China
- Publication Type:Review
- Keywords:
Peritoneal dialysis;
Ultrafiltration;
Sodium removal
- From:
Chinese Journal of General Practitioners
2020;19(1):72-75
- CountryChina
- Language:Chinese
-
Abstract:
Volume management is recognized as an important determinant of dialysis adequacy. The optimal ultrafiltration and sodium removal will improve the volume management and reduce the cardiovascular mortality. Automated peritoneal dialysis (APD), as one of renal replacement therapies, has become a choice for more and more patients with end-stage renal disease. APD allows an individualized dialysis prescription by providing more dialysis doses and more exchange times to improve ultrafiltration and sodium removal, achieving or even exceeding the efficacy of continuous ambulatory peritoneal dialysis. New strategies for volume control have emerged, including adapted APD, using icodextrin and low-sodium dialysate, to provide new ideas for APD prescription adjustment.