Determination of valproate in serum by precolumn derivatization HPLC
10.3969/j.issn.1006-0111.2016.03.016
- VernacularTitle:反相高效液相色谱-柱前衍生法测定人血清中丙戊酸浓度
- Author:
Bi CHEN
1
;
Xiaoliang HUANG
;
Hui LI
Author Information
1. 湖南省郴州市第一医院药学部
- Keywords:
valproate;
serum concentration;
derivatization;
HPLC
- From:
Journal of Pharmaceutical Practice
2016;34(3):255-257
- CountryChina
- Language:Chinese
-
Abstract:
Objective To establish a determination method for valprate in serum .Methods Serum sample was acidified by sulfuric acid and extracted with ethyl ether ,cyclohexanecarboxylic acid was selected as an internal standard ,α-bromoaceto-phenone as derivative reagent .Determination was performed with HPLC with methanol :water (70:30) as the mobile phase . The nalytical column was Eclipse Plus C18 (150 mm × 4 .6 mm ,5 μm) ,detected at 248 nm ,the flow rate was 1 .0 ml/min .Re-sults The linear rang of valproate was 8 .65~173 μg/ml .The mean relative recovery was bigger than 99 .27% .Both the rela-tive standard deviation (RSD) of inter-day and intra-day was less than 5% .Conclusions The method is rapid ,accurate ,sensi-tive and suitable for clinical therapeutic drug monitoring .