Sinus floor grafting using calcium phosphate nano-crystal coated xenogenic bone and autologous bone
- Author:
Kang Mi PANG
1
;
Bohan LI
;
Mohamed ALRASHIDAN
;
Sang Bae YOO
;
Mi Ae SUNG
;
Soung Min KIM
;
Jeong Won JAHNG
;
Myung Jin KIM
;
Jea Seung KO
;
Jong Ho LEE
Author Information
1. Department of Oral & Maxillofacial Surgery, College of Dentistry, Seoul National University #275-1 Yeongun-dong, Jongno-gu, Seoul, Korea.
- Publication Type:Original Article
- Keywords:
Calcium phosphate nano-crystal coated xenograft;
Sinus floor grafting;
Histomorphometric analysis
- MeSH:
Biopsy;
Bone Resorption;
Bone Substitutes;
Calcium;
Calcium Phosphates;
Capillaries;
Connective Tissue;
Dental Implants;
Floors and Floorcoverings;
Humans;
Maxilla;
Maxillary Sinus;
Osteogenesis;
Sinus Floor Augmentation;
Transplants
- From:Journal of the Korean Association of Maxillofacial Plastic and Reconstructive Surgeons
2009;31(3):243-248
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
or=2mm and < or=6mm. Lateral window approach was used, with grafting using Bio-ceraTM only(n=1) or mixed with autogenous bone from ramus and/or maxillary tuberosity(n=13). After 6 months of healing, implant sites were created with 3mm diameter trephine and biopsies taken for histomorphometric analysis. The parameters assessed were area fraction of new bone, graft material and connective tissue. Immediate and 6 months after grafting surgery, and 6 months after implantation, computed tomography (CT) was taken and the sinus graft was evaluated morphometric analysis. After implant installation at the grafted area, the clinical outcome was checked.RESULTS:Histomorphometry was done in ten patients. Bio-ceraTM particles were surrounded by newly formed bone. The graft particles and newly formed bone were surrounded by connective tissue including small capillaries in some fields. Imaging processing revealed 24.86+/-7.59% of new bone, 38.20+/-13.19% connective tissue, and 36.92+/-14.51% of remaining Bio-ceraTM particles. All grafted sites received an implant, and in all cases sufficient bone height was achieved to install implants. The increase in ridge height was about 15.9+/-1.8mm immediately after operation (from 13mm to 19mm). After 6 months operation, ridge height was reduced about 11.5+/-13.5%. After implant installation, average marginal bone loss after 6 months was 0.3+/-0.15mm.CONCLUSION: Bio-ceraTM showed new bone formation similar with Bio-Oss(R) histomorphometrically and appeared to be an effective bone substitute in maxillary sinus augmentation procedure with the residual bone height from 2 to 6mm.]]>