Clinical results of Mini Maze procedure in atrial fibrillation patients with impaired left ventricular systolic function
- VernacularTitle:梅氏微创消融术治疗心房颤动合并左室收缩功能受损的疗效评价
- Author:
MA Nan
1
;
JIANG Zhaolei
1
;
MEI Ju
1
;
LU Rongxin
1
;
TANG Min
1
;
DING Fangbao
1
Author Information
1. Department of Cardiothoracic Surgery, Xinhua Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, 200092, P.R.China
- Publication Type:Journal Article
- Keywords:
Atrial fibrillation;
thoracoscopy;
ablation;
left ventricular dysfunction
- From:
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery
2020;27(01):68-72
- CountryChina
- Language:Chinese
-
Abstract:
Objective To study the clinical results of Mini Maze procedure in atrial fibrillation patients with impaired left ventricular systolic function. Methods From June 2010 to December 2017, 86 atrial fibrillation patients with impaired left ventricular systolic function received Mini Maze procedure including 54 males and 32 females, with an average age of 60.7±5.9 years. Among them, 12 were with paroxysmal, 27 were with persistent and 47 were with long-standing persistent atrial fibrillation. The mean atrial fibrillation duration was 6.5±4.8 years. CHA2DS2-VASc score was 2.2±1.1. The mean diameter of left atrium was 46.9±3.8 mm. The mean diameter of left ventricle was 51.7±4.6 mm. The preoperative ejection fraction was 42.2%±4.7%. All patients received Mini Maze procedure after general anesthesia. The ablation included 3 annular ablations and 3 linear ablations. The left atrial appendage was excised by Endo-Gia. Ablation of Marshall ligament and epicardial autonomic ganglions were made by an ablation pen. Results Eighty-six patients successfully completed the procedure without transition to thoracotomy. There was no death during the perioperative period. Seventy-seven patients (89.5%) maintained sinus rhythm at discharge. Eighty patients were followed up for 27.2±12.1 months and 72 patients maintained sinus rhythm. The overall postoperative left ventricular ejection fraction was 47.1%±6.2%. The ejection fraction of the postoperative sinus rhythm group was 48.2%±5.8%, and the ejection fraction of the non-sinus group was 41.6%±5.8% (P<0.05). Multivariate regression analysis showed a left atrial diameter (HR=1.485, 95%CI 1.157-1.906, P<0.05) and an increase in ejection fraction over 10% (HR=18.800, 95%CI 1.674-189.289, P<0.05) were closely related to postoperative recurrence. Kaplan-Meier curve analysis showed that the recurrence rate of atrial fibrillation was significantly lower in patients with an increase in postoperative ejection fraction over 10% (P<0.05). Conclusion Mini Maze procedure is safe and effective in the treatment of atrial fibrillation patients with left ventricular systolic dysfunction, which helps to improve left ventricular function to prevent the vicious circle of atrial fibrillation and heart failure.