Effect of the application time of self-etching primers on the bonding of enamel.
10.5395/JKACD.2008.33.3.224
- Author:
Cheol Hee JIN
1
;
Young Gon CHO
;
Soo Mee KIM
;
Myeong Seon LEE
Author Information
1. Department of Conservative Dentistry, College of Dentistry, Chosun University, Korea. ygcho@chosun.ac.kr
- Publication Type:Original Article
- Keywords:
Application time;
Self-etching primers;
Microshear bond strength;
SEM;
Enamel
- MeSH:
Adhesives;
Crowns;
Dental Enamel;
Electronics;
Electrons;
Humans;
Molar
- From:Journal of Korean Academy of Conservative Dentistry
2008;33(3):224-234
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
The purpose of this study was to compare the normal and two times of application time of six self-etching primers applied to enamel using microshear bond strength (uSBS) test and the finding of scanning electronic microscope (SEM). Crown of sixty human molars were bisected mesiodistally and buccal and lingual enamel of crowns were partially exposed and polished with 600 grit SiC papers. They were divided into one of two equal groups subdivided into one of six equal groups (n = 10) by self-etching primer adhesives. After the same manufacture's adhesive resin and composites were bonded on the enamel surface of each group, the bonded specimens were subjected to uSBS testing and also observed under SEM. In conclusion, generally two times of primer application time increased the enamel uSBS, especially with the statistical increase of bond strength in adhesives involving high-pH primers.