Testing System for Biomechanical Properties of Bone.
10.3969/j.issn.1671-7104.2018.02.002
- Author:
Zhanshe GUO
1
;
Zhaojun GUO
1
;
Xiangdang LIANG
2
Author Information
1. School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing, 100191.
2. Department of Osteology, General Hospital of PLA, Beijing, 100853.
- Publication Type:Journal Article
- Keywords:
biomechanical properties;
fatigue experiment;
pull-pressure experiment;
test system
- MeSH:
Animals;
Biomechanical Phenomena;
Bone Screws;
Mechanical Phenomena;
Sheep;
Stress, Mechanical;
Tibia;
physiology
- From:
Chinese Journal of Medical Instrumentation
2018;42(2):84-87
- CountryChina
- Language:Chinese
-
Abstract:
A novel testing system is designed to simulate the mechanical performance and evaluate the biomechanical properties of the bone and the corresponding bone fixator. It is mainly composed of movement platform and servo motor system, sensors and hardware circuit system and software system. In order to prove the feasibility of the design, on the basis of the calibration for the force sensor, the fatigue experiment is carried out using the tibia of the sheep. It is concluded from the result that under the condition of 1 Hz in frequency, 50 kg in loading force and 18 000 cycles, the bone fixator can be still in good condition, which proves the feasibility of the design.