Extraction of Parameters for the Depth of Anesthesia Using Frequency Analysis Method.
10.4097/kjae.2005.49.5.606
- Author:
Jung Sam LEE
1
;
Ok Sik HAN
;
Hee Soong JUNG
;
Seong Wan BAIK
Author Information
1. Department of Anesthesia and Pain Medicine, Wallace Memorial Boptist Hospital, Busan, Korea. nonpain@paran.com
- Publication Type:Original Article
- Keywords:
anesthetic depth;
frequency analysis;
heart rate variability
- MeSH:
Anesthesia*;
Anesthesia, General;
Autonomic Nervous System;
Electrocardiography;
Enflurane;
Female;
Gynecologic Surgical Procedures;
Heart Rate;
Humans;
Noise
- From:Korean Journal of Anesthesiology
2005;49(5):606-611
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
BACKGROUND: General anesthesia alters autonomic nervous system activity. Evaluation of the autonomic nervous system activity using heart rate variability and so, evaluating the anesthetic depth was tried. METHODS: In thirty patients undergoing gynecological surgery under general inhalational anesthesia with enflurane, a 10-minute EKG was perioperatively acquired during main incidents. The heart rate variability was analyzed and expressed as 5-minute signals. RESULTS: In an analysis of the frequency area adopting the heart rate variability, both low and high frequencies represented the effects of the autonomic nervous system, but the low and high frequencies, their ratio and 1/f noise were not valuable in estimating the depth of anesthesia before, during and after the operation. The detrended fluctuation analysis also proved unsuitable for the estimation of the anesthetic depth during an operation. CONCLUSIONS: The signal using heart rate variability reflects the parameter of the autonomic nervous system during operations.