Cone-beam computed tomography-synthesized cephalograms for evaluating the vertical dimension of occlusions.
- Author:
Ya-Nan WEI
1
;
Zhi-Yun CAO
2
;
Gang LI
3
;
Xun SHENG
2
;
Yi-Qing XIONG
1
;
Wei LI
1
Author Information
- Publication Type:Journal Article
- Keywords: cone-beam computed tomography; edentulous; synthesized cephalograms; vertical dimension
- MeSH: Aged; Cephalometry; China; Cone-Beam Computed Tomography; Humans; Imaging, Three-Dimensional; Middle Aged; Mouth, Edentulous; Vertical Dimension
- From: West China Journal of Stomatology 2019;37(1):53-57
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:The accuracy of the occlusion vertical dimensions of edentulous Han patients from Yunnan province was compared and analyzed on the basis of cone-beam computed tomography (CBCT)-synthesized cephalograms, closest speaking space method, and interocclusal distance.
METHODS:A database correlating the CBCT head lateral images of Han patients from Yunnan province with normal occlusal conditions was first constructed. Then, five edentulous Han patients aged 63-78 years old from Yunnan Province were selected. NNT.View software was used to measure and analyze hard tissue cephalometric radiographs that had been transformed by the CBCT marker. The radiographs were then combined with the normal population database for the assessment of occlusion vertical dimensions. The occlusion vertical dimensions determined on the basis of CBCT-synthesized cephalograms, the closest speaking space method, and the free-way space were analyzed.
RESULTS:The closest speaking space method was used as the standard control group, the differences between seven methods and the closest speaking space method were analyzed. The seven methods include free-way space method and six CBCT-synthesized cephalograms methods (N-ANS/ANS-Me, S-Go/N-Me, ANS-Gn/N-ANS, ANS-FH/Me-FH, ANS-Xi-Pm, and CA/LA). The seven methods were highly consistent with the closest speaking space method (intraclass correlation coefficient>0.986). The absolute values of the differences between the methods of free-way space, N-ANS/ANS-Me, S-Go/N-Me and the closest speaking space method were lower than those of the other four groups (P<0.05), while the differences between ANS-FH/Me-FH and the closest speaking space method was higher than those other groups (P<0.05).
CONCLUSIONS:CBCT-synthesized cephalograms, with the exception of ANS-FH/Me-FH, can provide references for the clinical evaluation of the occlusion vertical dimensions of patients with edentulous jaws.