Isolated Musculocutaneous Nerve Palsy after the Reverse Total Shoulder Arthroplasty
10.5397/cise.2016.19.2.101
- Author:
Sung Guk KIM
1
;
Chang Hyuk CHOI
Author Information
1. Department of Orthopaedic Surgery, Daegu Catholic University Medical Center, Daegu, Korea. p10001@hanmail.net
- Publication Type:Case Report
- Keywords:
Rotator cuff arthropathy;
Musculocutaneous nerve palsy;
Reverse total shoulder arthroplasty
- MeSH:
Aged;
Arm;
Arthroplasty;
Humans;
Musculocutaneous Nerve;
Paralysis;
Radial Nerve;
Rotator Cuff;
Shoulder;
Tears;
Traction
- From:Journal of the Korean Shoulder and Elbow Society
2016;19(2):101-104
- CountryRepublic of Korea
- Language:English
-
Abstract:
Reverse total shoulder arthroplasty has been performed with promising results in rotator cuff tear arthropathy. However, the global complication of the reverse total shoulder arthroplasty is relatively higher than that of the conventional total shoulder arthroplasty. Neurologic complications after reverse total shoulder arthroplasty are rare but there are sometimes remaining sequelae. The cause of the neurologic complication is multifactorial, including arm traction, position and the design of the implant. Most cases of neurologic palsy following reverse total shoulder arthroplasty occur in the axillary nerve and the radial nerve. The authors report on a case of a 71-year-old man with isolated musculocutaneous nerve palsy after reveres total shoulder arthroplasty with related literature.