Arthroscopy Assisted 2 Cannulated Screw Fixation for Transverse Glenoid Fracture: A Case Report
10.5397/cise.2016.19.2.105
- Author:
Sam Guk PARK
1
Author Information
1. Department of Orthopedic Surgery, Yeungnam University Medical Center, Yeungnam University College of Medicine, Daegu, Korea. 70radiorth@naver.com
- Publication Type:Case Report
- Keywords:
Glenoid cavity;
Transverse fracture;
Arthroscopy;
Cannulated screw;
Perpendicular fixation
- MeSH:
Arthroscopy;
Glenoid Cavity;
Humans;
Intra-Articular Fractures;
Methods;
Thorax
- From:Journal of the Korean Shoulder and Elbow Society
2016;19(2):105-109
- CountryRepublic of Korea
- Language:English
-
Abstract:
Arthroscopy is recognized as an important adjunct in treatment of intra-articular fractures. The author reports on successful treatment of a displaced transverse glenoid cavity fracture, reduced and fixed with arthroscopic assist, using two cannulated screws perpendicular to the fracture surface, in a patient with frail chest. One screw passed through the Neviaser portal, and the other screw passed through the base of the coracoid process. Arthroscopy assisted reduction and 2 cannulated screw fixation through the Neviaser portal and coracoid base appears to be a good method for treatment of transverse glenoid fractures.