A Case of Left Ventricular Outflow Obstruction Caused by Mitral Valve Replacement.
10.4070/kcj.1998.28.1.113
- Author:
Do Yun KIM
;
Hong Keun CHO
;
Ick Mo CHUNG
;
Si Hoon PARK
;
Seong Hoon PARK
;
Gil Ja SHIN
;
Byung Chul CHANG
- Publication Type:Case Report
- Keywords:
Mitral valve replacement;
Left ventricular outflow obstruction
- MeSH:
Cardiac Catheterization;
Cardiac Catheters;
Diagnosis;
Echocardiography, Doppler;
Fibrosis;
Mitral Valve*;
Prognosis;
Ventricular Outflow Obstruction*
- From:Korean Circulation Journal
1998;28(1):113-117
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
The pathophysiology, clinical presentation and prognosis of left ventricular obstruction present an important cardiological problem. Various anatomical and functional abnormality can cause this phenomenon. Rarely, left ventricular outflow obstruction can result after mitral valve surgery. We experienced a case of left ventricular outflow obdtruction 13 years after mitral valve replavement. The diagnosis was made using two-dimensinal Doppler echocardiography and confirmed by cardiac catheterization. The pressure gradient across the left ventricular outflow obstruction was 96mmHg. A second mitral valve replacement was performed. Because severe fibrosis, pannis around the prosthetic mitral valve and a subaortic web were detected during the operation, the subaortic web was removes.