Open reduction and fixation with cannulated screws via the modified Burks-Schaffer approach versus arthroscopic EndoButton plating for avulsion fracture of the tibial attachment of the posterior cruciate ligament
10.3760/cma.j.issn.1671-7600.2019.05.003
- VernacularTitle:改良Burks-Schaffer入路切开复位空心钉固定与关节镜下Endobutton带袢钢板固定治疗后交叉韧带胫骨止点撕脱骨折的疗效比较
- Author:
Weijie LIU
1
;
Feng CHEN
;
Fagang YE
;
Chao QI
;
Haifeng GONG
;
Chengdong ZHANG
;
Kai WANG
;
Yuan QIAN
;
Xuwen LI
Author Information
1. 青岛大学附属医院创伤外科 266000
- Keywords:
Knee joint;
Arthroscopy;
Fracture fixation,internal;
Posterior cruciate ligament;
Avulsion fracture of the tibial attachment;
Modified Burks-Schaffer's approach
- From:
Chinese Journal of Orthopaedic Trauma
2019;21(5):378-383
- CountryChina
- Language:Chinese
-
Abstract:
Objective To compare the clinical outcomes between open reduction and fixation with cannulated screws via the modified Burks-Schaffer approach versus arthroscopic EndoButton plating for avulsion fracture of the tibial attachment of the posterior cruciate ligament(PCL).Methods From February 2013 to August 2017,41 patients with acute displaced avulsion fracture of the tibial PCL attachment were treated operatively at Department of Trauma Surgery,The Affiliated Hospital to Qingdao University.They were 24 men and 17 women,aged from 18 to 65 years (average,39 years).The lefi knee was injured in 22cases and the right knee in 19.They were divided into 2 groups according to their different fixation methods.The open reduction and fixation group (23 cases) received open reduction and fixation with cannulated screws via the modified Burks-Schaffer approach while the arthroscopic group (18 cases) arthroscopic Endobutton plating.The 2 groups were compared in terms of operation time,bleeding,objective knee scores and knee range of motion (ROM) after operation.Results All the 41 patients were followed up from 23 to 40months (average,27.2 months).Their follow-up revealed no incision infection,malunion,nonunion or loosening of the implants.Their knee X-ray films at the final follow-ups showed bony union of all the avulsion fractures.There were significant differences between the open reduction and fixation group and the arthroscopic group in operation time (52.6±7.3 min versus 86.8±9.2 min) and bleeding (63.9±12.7 mL versus 19.7 ± 10.2 mL) (P < 0.05).There was no significant difference in the objective knee scores or knee ROM between the 2 groups (P > 0.05).Conclusions Both open reduction and cannulated screw fixation via the modified Burks-Schaffer approach and arthroscopic EndoButton plating can achieve satisfactory clinical outcomes in the treatment of avulsion fracture of the tibial PCL attachment.Although the 2 methods make no significant differences in stability of the knee joint or in clinical scores,the latter leads to less bleeding and the former shorter operation time.