Reconstruction of the Transmitral Flow Rate Curve with M-Mode,2-Dimensional and Doppler Echocardiography -Validation Study-.
10.4070/kcj.1989.19.2.273
- Author:
Dong Woon KIM
;
Seung Woo PARK
;
Duk Kyung KIM
;
Kyu Hyung RYU
;
Byung Hee OH
;
Young Bae PARK
;
Yun Shik CHOI
;
Jung Don SEO
;
Young Woo LEE
- Publication Type:Original Article ; Validation Studies
- Keywords:
Pulsed Doppler echocardiography;
Transmitral flow rate curve;
Left ventricular filling volume curve;
Left ventriculography
- MeSH:
Angiography;
Echocardiography;
Echocardiography, Doppler*;
Echocardiography, Doppler, Pulsed;
Humans
- From:Korean Circulation Journal
1989;19(2):273-282
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
To validate ventricular diastolic phase parameters of reconstructed transmitral flow rate curve by M-mode, 2-dimensional and pulsed Doppler Echocardiography, these parameters were compared with same parameters by left ventriculography. The study population was 22 patients who received both coronary arteriography and echocardiographic examination. Transmitral flow rate curve and left ventricular filling volume curve were reconstructed from transmitral flow velocity curve by pulsed Doppler, mitral annulus diameter by two diameter by two dimensional and diastolic motion of both mitral leafltes by M-mode echocardiography. From left ventriculography, left ventricular filling volume curve and transmitral flow rate curve were made using area-length method by Sandler and Dodge. From trasmitral flow fraction, 1/2 diastolic time filling fraction, normalized peak filling volume, 1/3 diastolic time filling fraction, 1/2 diastolic time fraction, normalized peak early filling rate and ratio of early to late peak filling rate were measured. Correlation between same parameters derived from echocardiography and left ventriculography were observed. 1) Total diastolic filling volume:correlation coefficient r=0.47, P<0.05. 2) 1/3 diastolic time filling fraction:correlation coefficient r=0.90, P<0.001. 3) 1/2 diastolic time filling fraction:correlation coefficient r=0.80, P<0.001. 4) Normalized peak early filling rate:correlation coefficient r=0.57, P<0.01. 5) Ratio of early to late peak filling rate:correlation coefficient r=0.85, P<0.001. Therefore, left ventricular diastolic phase parameters of reconstructed transmitral flow rate curve using, M-mode, 2-dimensional and pulsed Doppler echocardiography seems to be useful for the noninvasive evaluation of the left ventricular diastolic function.