Early outcomes of totally endoscopic mitral valve repair with artificial
10.7507/1007-4848.201610016
- VernacularTitle:全胸腔镜人工腱索二尖瓣成形术的近期结果
- Author:
ZHU Ren
1
;
HUANG Huanlei
1
;
LIU Jian
1
;
GUO Huiming
1
;
XIE Bin
1
;
KE Yingjie
1
;
ZENG Qingshi
1
;
LU Cong
1
Author Information
1. Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, 510080, P.R.China
- Publication Type:Journal Article
- Keywords:
Minimally invasive surgery;
mitral valvuloplasty;
artificial chordae
- From:
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery
2017;24(10):787-790
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the outcomes and summarize the clinical experience of totally endoscopic mitral valve repair with artificial chordae implantation. Methods From May 2013 to June 2016, 71 patients with mitral valve insufficiency were admitted to our hospital who underwent totally endoscopic mitral valve repair with artificial chordae implantation. There were 47 males and 24 females with the age of 46.0±14.4 years ranging from 13-78 years. The pathogenesis included degenerative valvular diseases in 63 patients, congenital valvular diseases in 4, infectious endocarditis in 2, rheumatic disease in 1 and cardiomyopathy in 1. Prolapse of anterior, posterior, or both leaflets was present in 26 (36.6%), 19 (26.8%), and 25 (35.2%) patients, respectively; one patient (1.4%) presented valve annulus enlargement and thirteen were associated with commissure lesion. The mitral regurgitation area ranged from 4.2 to 26.3 cm2 (mean, 12.2±5.6 cm2). All the procedures were performed by total endoscopy under cardiac arrest. 5-0 Gore-tex sutures were used as the material of artificial chordae which was implanted one by one. Results There was no in-hospital death. One patient was transferred to mitral valve replacement, and one median sternotomy due to bleeding. The mean cardiopulmonary bypass time was 156.0±31.6 min and aortic cross-clamp time 110.0±20.1 min. We finally had 39 isolated mitral valve repair, 28 mitral valve repair combined tricuspid valve repair, 3 mitral valve repair combined atrial septal defect closure, and 1 mitral valve repair combined correction of partial anomalous pulmonary vein connection. Each patient was implanted artificial chordae of 2.5±1.7 (ranging from 1 to 7), and 65 patients received mitral annulus (full ring). The intraoperative transoesophageal echocardiography found no mitral regurgitation in 44 patients, the area of mitral regurgitation was 0-2 cm2 in 24, and 3 patients with mitral regurgitation>2 cm2 experienced serious systolic anterior motion. Of the 3 patients with systolic anterior motion (SAM), one transferred to mitral valve replacement, one underwent mitral re-repair, and one took conservative treatment. The mean follow-up was 12.7±10.5 months (range: 1 to 36 months), while 2 patients were lost to follow up with the follow-up rate of 97.2%. Recurrent severe regurgitation occured in 3 patients, moderate in 5, mild or trivial in 27 and no regurgitation in 36. During the follow-up, 1 patient died of myocardiopathy-induced heart failure post discharge, 1 suffered from cerebral infarction, and no patient underwent reoperation. Conclusion The totally endoscopic surgical treatment of mitral valvuloplasty with artificial chordae is reliable for patients with mitral valve prolapse, which provides favorable clinical efficacy and outcomes. The difficulty lies in how to determine the appropriate length of the chordae and keep the stability of length.