Multislice spiral CT diagnosis error analysis of children's airway foreign bodies.
- Author:
Junmei ZHANG
;
Bei SHEN
;
Zhiyong GUO
- Publication Type:Journal Article
- MeSH:
Bronchi;
Child, Preschool;
Diagnostic Errors;
Female;
Foreign Bodies;
diagnostic imaging;
Humans;
Infant;
Male;
Retrospective Studies;
Tomography, Spiral Computed;
methods
- From:
Journal of Clinical Otorhinolaryngology Head and Neck Surgery
2014;28(15):1158-1159
- CountryChina
- Language:Chinese
-
Abstract:
OBJECTIVE:Analysis of multislice CT (MSCT) on the misdiagnosis reasons of children bronchial foreign body, avoid missed diagnosis, to achieve reasonable application.
METHOD:Fourteen cases of misdiagnosed cases of data were retrospectively analyzed in our department of suspicious in children with bronchial foreign body, and discuss the misdiagnosis reasons.
RESULT:Fourteen cases of misdiagnosis of children with 9 cases by MSCT examination showed no obvious foreign matter. Through bronchoscopy intraoperative found foreign body, 5 cases by multislice CT (MSCT) to found foreign body, 4 cases of phlegm scabs, 1 case is inflammatory granulation, all recovered after treatment. Reasons of misdiagnosis were threshold selection error, scanning level from the inception glottis, imaging error, etc.