Value of ratio of optic nerve sheath diameter to eyeball transverse diameter in assessing intracranial pressure in patients with brain injury: measurement using ultrasound
10.3760/cma.j.issn.0254-1416.2018.11.024
- VernacularTitle:视神经鞘直径与眼球横径比值评估颅脑损伤患者颅内压的价值:超声法确定
- Author:
Jie DU
1
;
Yanjun DENG
;
Xiaoxin HE
;
Shigang QIAO
;
Chen WANG
Author Information
1. 215004,苏州大学附属第二医院麻醉科
- Keywords:
Optic nerve;
Eye;
Intracranial hypertension;
Craniocerebral trauma
- From:
Chinese Journal of Anesthesiology
2018;38(11):1369-1371
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the value of the ratio of optic nerve sheath diameter to eyeball transverse diameter (ONSD/ETD) in assessing intracranial pressure using ultrasound in the patients with brain injury.Methods Forty-six patients of both sexes with brain injury in the surgical intensive care unit,were selected.Craniotomy was performed within 24 h after admission to hospital,and the intracranial pressure probe was placed in the lateral cerebral ventricle of the enrolled patients who were aged 18-80 yr,with Glasgow Coma Scale score 3-15.ONSD and ETD were measured within 3 days after operation,three times a day,and the intracranial pressure was simultaneously recorded.The correlation between ONSD/ETD ratio and intracranial pressure were analyzed using the Pearson correlation analysis.The receiver operating characteristic curve was used to evaluate the accuracy of ONSD/ETD ratio in assessing the intracranial hypertension (intracranial pressure>20 mmHg).Results The ONSD/ETD ratio was positively correlated with intracranial pressure (r =0.720,P<0.01).The area under the receiver operating characteristic curve was 0.900 (95% confidence interval 0.854-0.946),and the threshold was 0.248 (sensitivity 89.4%,specificity 77.5%).Conclusion The ONSD/ETD ratio produces higher accuracy in assessing intracranial pressure in the patients with brain injury.