An assessment of accuracy of half-guided implant surgery using implant surgical guide: A case report
10.4047/jkap.2019.57.2.150
- Author:
Choongkil KIM
1
;
Wonsup LEE
;
Ho Beom KWON
Author Information
1. Dental Research Institute and Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul National University Dental Hospital, Seoul, Republic of Korea. proskwon@snu.ac.kr
- Publication Type:Case Report
- Keywords:
Dental implants;
Computer-assisted;
Jaw, Edentulous, Partially
- MeSH:
Dental Implants;
Humans;
Jaw, Edentulous, Partially;
Methods;
Periodontal Diseases;
Prostheses and Implants;
Tooth;
Tooth Fractures
- From:The Journal of Korean Academy of Prosthodontics
2019;57(2):150-159
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
Nowadays, dental implant is one of the widely used treatment options for edentulous patients. Recently, a method of improving the accuracy of implant surgery using an implant surgical guide has been introduced and widely used in order to accurately place the implant in a proper position. Full-guided and half-guided implant surgery can be distinguished according to the level of surgical guide application during the implant surgery. It is true that full-guided implant surgery exhibits higher accuracy, but half-guided implant surgery is often performed in a clinical situation due to the factors such as the circumstances of the operation. A partially edentulous patient who lost teeth due to tooth fracture and periodontal disease was treated using implant and fixed prosthesis. Half-guided implant surgery was performed using an implant surgical guide during implant surgery, the accuracy of implant placement was analyzed.