Hemoperitoneum: a complication of loop electrosurgical excision procedure
10.5468/ogs.2019.62.2.138
- Author:
Angela CHO
1
;
Sunwha PARK
;
Soyun PARK
;
Hye Sim KANG
;
Soon Sup SHIM
;
Chul Min PARK
;
Sung Yob KIM
Author Information
1. Department of Obstetrics and Gynecology, Ewha Womans University Mokdong Hospital, Seoul, Korea.
- Publication Type:Case Report
- Keywords:
Conization;
Laparoscopy;
Hemoperitoneum
- MeSH:
Cervical Intraepithelial Neoplasia;
Conization;
Hemoperitoneum;
Humans;
Laparoscopy;
Uterine Perforation;
Uterus
- From:Obstetrics & Gynecology Science
2019;62(2):138-141
- CountryRepublic of Korea
- Language:English
-
Abstract:
Loop electrosurgical excision procedure (LEEP) is commonly performed for the management of cervical intraepithelial neoplasia. Although LEEP is considered to be a relatively simple procedure, several unexpected complications have been reported in the literature. Herein, we report a case of hemoperitoneum caused by uterine perforation following LEEP. Blood collection in pelvic cavity and two small defects of the uterus were confirmed by diagnostic laparoscopy. The defects were sutured and the patient recovered well after the operation.