Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging
- Author:
Yuehua LI
1
;
Mingyuan YUAN
;
Mengmeng YU
;
Zhigang LU
;
Chengxing SHEN
;
Yining WANG
;
Bin LU
;
Jiayin ZHANG
Author Information
- Publication Type:Original Article
- Keywords: Coronary artery disease; Multidetector computed tomography; Angiography; Stents; Percutaneous coronary intervention
- MeSH: Angiography; Blood Volume; Contrast Media; Coronary Artery Disease; Heart Ventricles; Humans; Male; Multidetector Computed Tomography; Myocardial Perfusion Imaging; Percutaneous Coronary Intervention; Prevalence; Prospective Studies; Stents; Veins
- From:Korean Journal of Radiology 2019;20(4):621-630
- CountryRepublic of Korea
- Language:English
- Abstract: OBJECTIVE: To study the prevalence and clinical characteristics of decreased myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) in symptomatic patients without in-stent restenosis. MATERIALS AND METHODS: Thirty-seven (mean age, 71.3 ± 10 years; age range, 48–88 years; 31 males, 6 females) consecutive symptomatic patients with patent coronary stents and without obstructive de novo lesions were prospectively enrolled to undergo dynamic CT-MPI using a third-generation dual-source CT scanner. The shuttle-mode acquisition technique was used to image the complete left ventricle. A bolus of contrast media (50 mL; iopromide, 370 mg iodine/mL) was injected into the antecubital vein at a rate of 6 mL/s, followed by a 40-mL saline flush. The mean MBF value and other quantitative parameters were measured for each segment of both stented-vessel territories and reference territories. The MBFratio was defined as the ratio of the mean MBF value of the whole stent-vessel territory to that of the whole reference territory. An MBFratio of 0.85 was used as the cut-off value to distinguish hypoperfused from non-hypoperfused segments. RESULTS: A total of 629 segments of 37 patients were ultimately included for analysis. The mean effective dose of dynamic CT-MPI was 3.1 ± 1.2 mSv (range, 1.7–6.3 mSv). The mean MBF of stent-vessel territories was decreased in 19 lesions and 81 segments. Compared to stent-vessel territories without hypoperfusion, the mean MBF and myocardial blood volume were markedly lower in hypoperfused stent-vessel territories (77.5 ± 16.6 mL/100 mL/min vs. 140.4 ± 24.1 mL/100 mL/min [p < 0.001] and 6.4 ± 3.7 mL/100 mL vs. 11.5 ± 4 mL/100 mL [p < 0.001, respectively]). Myocardial hypoperfusion in stent-vessel territories was present in 48.6% (18/37) of patients. None of clinical parameters differed statistically significantly between hypoperfusion and non-hypoperfusion subgroups. CONCLUSION: Decreased MBF is commonly present in patients who are symptomatic after percutaneous coronary intervention, despite patent stents and can be detected by dynamic CT-MPI using a low radiation dose.