Efficacy of Interavascular Ultrasound in the Palmaz-Schatz Stent Implantation: Clinical Experience of 3 Coronary Artery Disease Patients
10.4250/jkse.1994.2.2.209
- Author:
Moo Hyun KIM
1
;
Yong Kyu LEE
;
Byung Soo KIM
;
Chang Ho YANG
;
Hyun Kuk DO
;
Young Dae KIM
;
Jong Seong KIM
Author Information
1. Department of Internal Medicine, College of Medicine, Dong-A University and Saedongrae Hospital, Pusan, Korea.
- Publication Type:Case Report
- Keywords:
Intravascular ultrasound;
Palmaz-schatz stent
- MeSH:
Coronary Artery Disease;
Coronary Vessels;
Dilatation;
Humans;
Methods;
Stents;
Ultrasonography
- From:Journal of the Korean Society of Echocardiography
1994;2(2):209-214
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
Intravascular ultrasound is a usful too to assess the adequate stent strut expansion after stent implantation and nowadays it can bo also used as a dicision making method about omitting anticoagulant therapy. We used intravascular ultrasound before and after Palmz-schatz stent implantation in 3 patients with coronary artery narrowings and analysed serial post porcedure lumen diameter, cross sectional area. We think it is a useful tool to assess the effect of stent implantation and post stent balloon dilatation.