Immediate loading of mandibular single implant by using surgical guide and modeless digital prosthesis: a case report
10.14368/jdras.2017.33.4.299
- Author:
Hyun jeong LIM
1
;
Myung Joo KIM
;
Ho Beom KWON
;
Young Jun LIM
Author Information
1. Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea. limdds@snu.ac.kr
- Publication Type:Case Report
- Keywords:
digital impression;
surgical guide;
CAD/CAM;
immediate loading;
intraoral scanner
- MeSH:
Crowns;
Esthetics;
Humans;
Molar;
Patient Satisfaction;
Prostheses and Implants;
Tooth
- From:Journal of Dental Rehabilitation and Applied Science
2017;33(4):299-306
- CountryRepublic of Korea
- Language:Korean
-
Abstract:
In this case report, immediate loading of an implant-supported single-tooth prosthesis through complete digital workflow. A patient presented for restoration of missing a single tooth in the mandibular first molar. The digital impression was made with intraoral scanner and implant was placed using surgical guide pre-fabricated with pre-operative computed tomography (CT) and scan data. After 1 week later, prefabricated customized abutment and provisional restoration were connected for immediate loading. After 8 weeks later, abutment level impression was taken by intraoral scanner. At 3 months later from implant installation, monolithic zirconia crown were fabricated. This clinical report presents satisfying result in accuracy and patient satisfaction. A completely modeless digital procedure met expectations regarding precision, esthetics, and functionality.